EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Untargeted Multiple Reaction Monitoring

Winnie Uritboonthai, Aries Aisporna, Linh Hoang, Bill Webb, Elizabeth M Billings iD, Corey Hoang, Mirna Tobea, Chelsea C Cates-Gatto, Amanda J Roberts, Tony Teav, Rebecca Borreggine, Ioana Kyritsi und 6 weitere

Analytical Chemistry · 31.03.2026 · 98 (12) · 8985-8994

DOI: 10.1021/acs.analchem.5c06838 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 17.03.2026. Verfasst von Winnie Uritboonthai und 17 weiteren Autor:innen. Beteiligte Einrichtung: Scripps Center for Metabolomics and Mass Spectrometry, The Scripps Research Institute, La Jolla, California 92037, United States. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NCI NIH HHS, National Cancer Institute, National Institute of General Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Multiple reaction monitoring (MRM) enables robust and sensitive quantification but traditionally requires predefined precursor-fragment transitions, limiting its use in discovery-driven studies. Here, we describe untargeted/micro/universal multiple reaction monitoring (uMRM), a workflow that converts high-resolution untargeted liquid chromatography-mass spectrometry/MS (LC-MS/MS) data into scheduled triple-quadrupole MRM transitions. Pooled-sample LC-MS and stepped-energy DDA MS/MS acquisitions (0, 10, 20, and 40 eV) are used to capture precursor and fragment information representative of each experimental set. Detected features undergo automated deisotoping and empirically validated in-source fragment filtering, followed by spline-based modeling of collision-energy-dependent fragmentation to define optimized precursor-fragment transitions. Transitions are scheduled using retention times observed in pooled samples and deployed on triple-quadrupole instruments without requiring nonlinear retention-time alignment or authentic standards. Across representative biological matrices, including urine, brain tissue, and cultured cells, uMRM enabled automated generation of quantitative MRM methods from untargeted discovery data. Benchmarking across seven triple-quadrupole platforms demonstrated strong agreement between uMRM-derived and experimentally optimized collision energies. By converting discovery-scale data sets into compact transition tables suitable for quantitative deployment, uMRM provides a reproducible approach for linking untargeted LC-MS/MS acquisition with targeted quantitation.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryLiquid Chromatography-Mass SpectrometryAnimalsHumansChromatography, Liquid

Autor:innen und Institutionen

  • Scripps Center for Metabolomics and Mass Spectrometry, The Scripps Research Institute, La Jolla, California 92037, United States.
  • Gnotobiotic and Cryobank Facility, The Scripps Research Institute, La Jolla, California 92037, United States.
  • Animal Models Core Facility, The Scripps Research Institute, La Jolla, California 92037, United States.
  • Metabolomics and Lipidomics Platform, Faculty of Biology and Medicine, University of Lausanne, Lausanne CH-1015, Switzerland.
  • Department of Integrative Structural and Computational Biology, Department of Chemistry, The Scripps Research Institute, La Jolla, California 92037, United States.
  • The Skaggs Institute for Chemical Biology, The Scripps Research Institute, La Jolla, California 92037, United States.

ORCID-Profile: Elizabeth M Billings, Julijana Ivanisevic, Robert Plumb, Gary Siuzdak

Förderung

  • NCI NIH HHS
  • National Cancer Institute
  • National Institute of General Medical Sciences

Zitieren

APA

Uritboonthai, W., Aisporna, A., Hoang, L., Webb, B., Billings, E. M., Hoang, C., Tobea, M., Cates-Gatto, C. C., Roberts, A. J., Teav, T., Borreggine, R., Kyritsi, I., Gallart-Ayala, H., Ivanisevic, J., Popova, A., Williamson, J. R., Plumb, R., & Siuzdak, G. (2026). Untargeted Multiple Reaction Monitoring. Analytical Chemistry, 98(12), 8985-8994. https://doi.org/10.1021/acs.analchem.5c06838

Vancouver

Uritboonthai W, Aisporna A, Hoang L, Webb B, Billings EM, Hoang C, et al. Untargeted Multiple Reaction Monitoring. Analytical Chemistry. 2026;98(12):8985-8994. doi:10.1021/acs.analchem.5c06838

BibTeX
@article{Uritboonthai2026,
  author = {Uritboonthai, Winnie and Aisporna, Aries and Hoang, Linh and Webb, Bill and Billings, Elizabeth M and Hoang, Corey and Tobea, Mirna and Cates-Gatto, Chelsea C and Roberts, Amanda J and Teav, Tony and Borreggine, Rebecca and Kyritsi, Ioana and Gallart-Ayala, Hector and Ivanisevic, Julijana and Popova, Anna and Williamson, James R and Plumb, Robert and Siuzdak, Gary},
  title = {Untargeted Multiple Reaction Monitoring},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {12},
  pages = {8985--8994},
  doi = {10.1021/acs.analchem.5c06838}
}
Kostenlos starten →