EUVIMEDEUVIMED entdecken
Crossref

Axially-Staggered-Trap Microplasma Source-Based Miniaturized Optical Emission Spectrometer for High-Performance Elemental Detection

Meng Zhang, Qingsong Tang, Kai Li, Chenghui Li, Xiandeng Hou iD, Xiaoming Jiang iD

Analytical Chemistry · 13.01.2026 · 98 (1) · 1057-1066

DOI: 10.1021/acs.analchem.5c06636 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 08.12.2025. Verfasst von Meng Zhang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Analytical & Testing Center, Sichuan University, Chengdu, Sichuan 610064, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 49 Literaturangaben. Gefördert von: Science and Technology Department of Sichuan Province, Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To miniaturize a microplasma-based optical emission spectrometer with high performance, the spatial distribution of electron density and the spectral responses in a point-discharge (PD) microplasma were systematically studied. COMSOL simulations and simultaneous detection of atomic emission and absorption were designed for spectral characterization. The discharge region around the electrode tips exhibited the highest electron density and spectral intensity. Based on this, a critical excitation source was designed by sequentially arranging three PDs in a discharge chamber. They were symmetrically distributed and axially rotated 60° between each other, forming an axially staggered-trap microplasma source to improve excitation capability and efficiency. This design exposed all of the electrode tips and enlarged the discharge region along the sample transportation/excitation and spectral acquisition direction, forming a microplasma trap. Therefore, it could intercept most analytes and facilitate spatially uniform excitation and unobstructed acquisition of spectral signals from all the electrode tips. Besides, the array configuration enabled tandem excitation to further improve sensitivity. Through coupling with hydride generation for sample introduction, limits of detection of 0.4, 0.1, 0.03, 0.2, 0.1, 1, and 0.05 μg L –1 were achieved for As, Ge, Hg, Pb, Sb, Se, and Sn, respectively, with relative standard deviations below 3% ( n = 5). Compared with a conventional single PD, the analytical sensitivities were improved by 5–7 times, and additionally by 8–17 times with more (six) PDs. The accuracy and applicability were demonstrated by analyzing certified reference materials and real samples. It features compactness, low power consumption, and excellent performance, thus showing great promise for on-site elemental analysis.

Autor:innen und Institutionen

  • Analytical & Testing Center, Sichuan University, Chengdu, Sichuan 610064, China.
  • Center for Archaeological Science, Sichuan University, Chengdu, Sichuan 610064, China.
  • National and Local Joint Engineering Laboratory for Energy Plant Bio-oil Production and Application, Key Laboratory of Green Chemistry and Technology (Ministry of Education), and College of Chemistry, Sichuan University…

ORCID-Profile: Xiandeng Hou, Xiaoming Jiang

Förderung

  • Science and Technology Department of Sichuan Province
  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China

Zitieren

APA

Zhang, M., Tang, Q., Li, K., Li, C., Hou, X., & Jiang, X. (2026). Axially-Staggered-Trap Microplasma Source-Based Miniaturized Optical Emission Spectrometer for High-Performance Elemental Detection. Analytical Chemistry, 98(1), 1057-1066. https://doi.org/10.1021/acs.analchem.5c06636

Vancouver

Zhang M, Tang Q, Li K, Li C, Hou X, Jiang X. Axially-Staggered-Trap Microplasma Source-Based Miniaturized Optical Emission Spectrometer for High-Performance Elemental Detection. Analytical Chemistry. 2026;98(1):1057-1066. doi:10.1021/acs.analchem.5c06636

BibTeX
@article{Zhang2026,
  author = {Zhang, Meng and Tang, Qingsong and Li, Kai and Li, Chenghui and Hou, Xiandeng and Jiang, Xiaoming},
  title = {Axially-Staggered-Trap Microplasma Source-Based Miniaturized Optical Emission Spectrometer for High-Performance Elemental Detection},
  journal = {Analytical Chemistry},
  year = {2026},
  volume = {98},
  number = {1},
  pages = {1057--1066},
  doi = {10.1021/acs.analchem.5c06636}
}
Kostenlos starten →