EUVIMEDEUVIMED entdecken
Crossref

In-Line Blend Potency Measurements of Low-Dose Formulations Using a Novel Deep-UV LIF Probe in the Feed Frame of a Rotary Tablet Press

Louis Bouckaert iD, Rohit Bhartia, Zhenqi Shi, Ray Reid, Ken Nguyen, Jason Micklewright, William Hug, Andrew Anderson, Tom Van Den Kerkhof, Mario Hellings, Philip Deamer, Ke Hong und 9 weitere

Analytical Chemistry · 2026

DOI: 10.1021/acs.analchem.5c06314 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Louis Bouckaert und 20 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of Pharmaceutical Technology, Ghent University, Ottergemsesteenweg 460, Ghent 9000, Belgium. Hauptthemen laut MEDLINE: Tablets, Ultraviolet Rays, Caffeine, Indomethacin. Die Arbeit nennt 34 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The increasing demand for nondestructive quantification of active pharmaceutical ingredients in low-dose formulations has highlighted the sensitivity limitations of existing in-line process analytical technology tools. This study integrates a deep-UV light-induced fluorescence (LIF) sensor into the feed frame of a rotary tablet press for in-line monitoring of blend potency. Two five-component, low-dose model formulations containing caffeine or indomethacin were evaluated. Partial Least Squares (PLS) regression was used to calibrate models based on spectra collected across a range of blend potencies (0.65 to 1.35%w/w), three paddle speeds, and two filler ratios. Instrument-related variability was assessed through verification runs at 1.00%w/w drug load using a second LIF spectrometer prototype. Step-change experiments (1.00% → 0.90% → 1.10%w/w) were conducted to evaluate model performance for the two instruments. Results showed that higher paddle speeds and increased formulation density enhanced LIF response. Instrument-to-instrument and day-to-day variability were observed but were mitigated through chemometric modeling. After evaluating development and performance metrics, the LIF sensor demonstrated adequate sensitivity and robust performance, supporting its potential application as an in-line PAT tool for the continuous manufacturing of low-dose formulations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TabletsUltraviolet RaysCaffeineIndomethacinLeast-Squares AnalysisSpectrometry, FluorescenceBulk Drugs

Substanzen

TabletsCaffeineIndomethacinBulk Drugs

Autor:innen und Institutionen

  • Laboratory of Pharmaceutical Technology, Ghent University, Ottergemsesteenweg 460, Ghent 9000, Belgium.
  • Photon Systems Inc., Covina, California 91722, United States.
  • Synthetic Molecule Pharmaceutical Sciences, Genentech - A Member of Roche Company, South San Francisco, California 94080, United States.
  • Analytical Development, Discovery Product Development and Supply, Johnson & Johnson Innovative Medicine, Beerse 2340, Belgium.
  • Process Engineering & Analytics, Global Supply Chain, GSK, Ware SG12 ODJ, U.K.
  • Manufacturing Intelligence and Global Automation, Pfizer Global Supply, Pfizer Inc., Peapack, New Jersey 07977, United States.

ORCID-Profile: Louis Bouckaert

Zitieren

APA

Bouckaert, L., Bhartia, R., Shi, Z., Reid, R., Nguyen, K., Micklewright, J., Hug, W., Anderson, A., Van Den Kerkhof, T., Hellings, M., Deamer, P., Hong, K., Brush, P., Vermeire, T., Xiang, D., Doddridge, G., Lambertus, G., Mendes de Oliveira, D., Vervaet, C., …, & De Beer, T. (2026). In-Line Blend Potency Measurements of Low-Dose Formulations Using a Novel Deep-UV LIF Probe in the Feed Frame of a Rotary Tablet Press. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c06314

Vancouver

Bouckaert L, Bhartia R, Shi Z, Reid R, Nguyen K, Micklewright J, et al. In-Line Blend Potency Measurements of Low-Dose Formulations Using a Novel Deep-UV LIF Probe in the Feed Frame of a Rotary Tablet Press. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.5c06314

BibTeX
@article{Bouckaert2026,
  author = {Bouckaert, Louis and Bhartia, Rohit and Shi, Zhenqi and Reid, Ray and Nguyen, Ken and Micklewright, Jason and Hug, William and Anderson, Andrew and Van Den Kerkhof, Tom and Hellings, Mario and Deamer, Philip and Hong, Ke and Brush, Peter and Vermeire, Tomas and Xiang, Dong and Doddridge, Gregory and Lambertus, Gordon and Mendes de Oliveira, Denilson and Vervaet, Chris and Vanhoorne, Valérie and De Beer, Thomas},
  title = {In-Line Blend Potency Measurements of Low-Dose Formulations Using a Novel Deep-UV LIF Probe in the Feed Frame of a Rotary Tablet Press},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.5c06314}
}
Kostenlos starten →