EUVIMEDEUVIMED entdecken
Crossref

Simultaneous Detection of Hydrogen and Acetylene Using a Photoacoustic Gas Sensor Based on Frequency Tracking and WMS-2 f Technique

Zhiyu Feng, Dajuan Lv, Liangming Xiong, Shiyu Yan, Wenzhe Wang, Lili Peng, Ping Lu, Chaotan Sima iD

Analytical Chemistry · 09.12.2025 · 97 (48) · 26738-26747

DOI: 10.1021/acs.analchem.5c05394 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 21.11.2025. Verfasst von Zhiyu Feng und 7 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Optical Fiber and Cable Manufacture Technology, Yangtze Optical Fibre and Cable Joint Stock Limited Company (YOFC), Wuhan 430…. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: Huazhong University of Science and Technology, National Natural Science Foundation of China, Open Projects Foundation of State Key Laboratory of Optical Fiber and Cable Manufacture Technology.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Insulating materials in high-voltage electrical equipment are subject to decomposition during the early stages of faults, with the release of characteristic gases such as hydrogen (H 2 ) and acetylene (C 2 H 2 ). However, the current gas detection methods suffer from issues like cross-sensitivity, compactness, and reliability. This paper proposes a photoacoustic spectroscopy (PAS) gas sensor based on a single DFB laser for the simultaneous detection of H 2 and C 2 H 2 . Specifically, C 2 H 2 serves both as a pump gas for assisting H 2 detection and as the target gas itself. Gas detection is implemented by tracking frequency shift caused by changes in sound velocity and extracting harmonic component generated by infrared absorption. By investigating the attenuation effect of H 2 gas on PA signals, a calibration model is established, correlating C 2 H 2 concentration with the harmonic peak under different H 2 concentrations. Through Allan deviation analysis, the system achieved minimum detection limits (MDLs) of 96 ppm for H 2 at 5.6 s integration time and 0.73 ppb for C 2 H 2 at 894 s. The developed system enables integrated gas analysis in hydrogen-rich environments, showing practical potential for in situ monitoring in power systems.

Autor:innen und Institutionen

  • State Key Laboratory of Optical Fiber and Cable Manufacture Technology, Yangtze Optical Fibre and Cable Joint Stock Limited Company (YOFC), Wuhan 430073, China.
  • National Engineering Research Center for Next Generation Internet Access System, School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China.
  • China Offshore Oil Engineering Limited Company, Tianjin Port Free Trade Zone, Tianjin 300461, China.

ORCID-Profile: Chaotan Sima

Förderung

  • Huazhong University of Science and Technology
  • National Natural Science Foundation of China
  • Open Projects Foundation of State Key Laboratory of Optical Fiber and Cable Manufacture Technology

Zitieren

APA

Feng, Z., Lv, D., Xiong, L., Yan, S., Wang, W., Peng, L., Lu, P., & Sima, C. (2025). Simultaneous Detection of Hydrogen and Acetylene Using a Photoacoustic Gas Sensor Based on Frequency Tracking and WMS-2 f Technique. Analytical Chemistry, 97(48), 26738-26747. https://doi.org/10.1021/acs.analchem.5c05394

Vancouver

Feng Z, Lv D, Xiong L, Yan S, Wang W, Peng L, et al. Simultaneous Detection of Hydrogen and Acetylene Using a Photoacoustic Gas Sensor Based on Frequency Tracking and WMS-2 f Technique. Analytical Chemistry. 2025;97(48):26738-26747. doi:10.1021/acs.analchem.5c05394

BibTeX
@article{Feng2025,
  author = {Feng, Zhiyu and Lv, Dajuan and Xiong, Liangming and Yan, Shiyu and Wang, Wenzhe and Peng, Lili and Lu, Ping and Sima, Chaotan},
  title = {Simultaneous Detection of Hydrogen and Acetylene Using a Photoacoustic Gas Sensor Based on Frequency Tracking and WMS-2 f Technique},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {48},
  pages = {26738--26747},
  doi = {10.1021/acs.analchem.5c05394}
}
Kostenlos starten →