EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

A Robust Isotope Ratio LC–MS/MS Workflow for High-Throughput Metabolic Profiling of Bacteria

Catarina Rocha, Sergi Pujol Pinto, Sheila Ingemann Jensen iD, Lars Keld Nielsen iD, Stefano Donati iD

Analytical Chemistry · 2026

DOI: 10.1021/acs.analchem.5c04931 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Catarina Rocha und 4 weiteren Autor:innen. Beteiligte Einrichtung: The Novo Nordisk Foundation Biotechnology Research Institute for the Green Transition, Technical University of Denmark, Kongens Lyngby2800, Denmark. Hauptthemen laut MEDLINE: Tandem Mass Spectrometry, Metabolomics, Bacteria, High-Throughput Screening Assays. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Novo Nordisk Fonden.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Stable isotope dilution mass spectrometry (IDMS) has become a cornerstone of quantitative metabolomics, enabling accurate intracellular metabolite quantification across a range of biological systems. However, the broader adoption of IDMS in high-throughput studies remains limited by the high costs of commercially available 13C-labeled internal standards (ISs), labor-intensive in-house IS production, and the narrow applicability of existing methods to different organisms. Here, we present a robust and scalable IDMS-based LC–MS/MS workflow for the high-throughput profiling of primary metabolism in diverse bacteria. The analytical method couples ion-pairing liquid chromatography with multiple reaction monitoring (MRM) to quantify 96 intracellular metabolites in under 16 min, with an average RSD of 21%. We developed a protocol for large-scale production of high-quality 13C-labeled IS, considerably lowering the costs and labor necessary to perform high-throughput IDMS studies. We then demonstrated the applicability of the same workflow by performing relative quantification of 5 diverse bacterial species in different cultivation conditions. This work provides a versatile platform for microbial metabolomics, supporting systems biology and data-driven metabolic engineering at scale.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tandem Mass SpectrometryMetabolomicsBacteriaHigh-Throughput Screening AssaysLiquid Chromatography-Mass SpectrometryCarbon IsotopesIsotope LabelingWorkflowChromatography, Liquid

Substanzen

Carbon IsotopesCarbon-13

Autor:innen und Institutionen

  • The Novo Nordisk Foundation Biotechnology Research Institute for the Green Transition, Technical University of Denmark, Kongens Lyngby2800, Denmark.
  • Australian Institute for Bioengineering and Nanotechnology (AIBN), The University of Queensland, Brisbane4072Queensland, Australia.
  • ARcCentre of Excellence in Synthetic Biology, The University of Queensland, Brisbane4072Queensland, Australia.

ORCID-Profile: Sheila Ingemann Jensen, Lars Keld Nielsen, Stefano Donati

Förderung

  • Novo Nordisk Fonden

Zitieren

APA

Rocha, C., Pinto, S. P., Jensen, S. I., Nielsen, L. K., & Donati, S. (2026). A Robust Isotope Ratio LC–MS/MS Workflow for High-Throughput Metabolic Profiling of Bacteria. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c04931

Vancouver

Rocha C, Pinto SP, Jensen SI, Nielsen LK, Donati S. A Robust Isotope Ratio LC–MS/MS Workflow for High-Throughput Metabolic Profiling of Bacteria. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.5c04931

BibTeX
@article{Rocha2026,
  author = {Rocha, Catarina and Pinto, Sergi Pujol and Jensen, Sheila Ingemann and Nielsen, Lars Keld and Donati, Stefano},
  title = {A Robust Isotope Ratio LC–MS/MS Workflow for High-Throughput Metabolic Profiling of Bacteria},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.5c04931}
}
Kostenlos starten →