EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-Efficiency Analytical Protein A Columns for High Sensitivity Monoclonal Antibody Titer Analysis

Beatrice Muriithi iD, Fabrice Gritti iD, Martin Gilar, Yeliz Sarisozen, Matthew Lauber, Kevin Wyndham

Analytical Chemistry · 09.12.2025 · 97 (48) · 26349-26356

DOI: 10.1021/acs.analchem.5c04766 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 18.11.2025. Verfasst von Beatrice Muriithi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, USA. Hauptthemen laut MEDLINE: Antibodies, Monoclonal, Staphylococcal Protein A, Chromatography, Affinity. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The quantification of monoclonal antibodies (mAbs) using analytical Protein A affinity chromatography HPLC columns with porous particles of 20 μm or larger diameters is a common method in bioprocessing analytics. The limitations of this method are long run times, relatively broad peaks, and low sensitivity. To address this, we developed an analytical Protein A column packed with 3.5 μm nonporous particles in organosilica-modified hardware, designed to minimize nonspecific binding of mAbs and enable rapid, reproducible, and sensitive measurements. Experimental and theoretical results show that smaller, nonporous particles reduce analyte axial dispersion and mass transfer-related band broadening. This leads to three times narrower peaks and greater peak heights compared to those obtained with 20 μm fully porous particles. Although the column with 3.5 μm nonporous particles has more than ten times less surface area and 50% less Protein A density, its dynamic binding capacity is 62% at 10% breakthrough compared to a column of the same size packed with 20 μm porous particles. This implies that not all of the available surface area or ligand capacity is accessible for binding for the fully porous particles. Both columns demonstrated greater than 98% recovery and a low carryover of less than 0.3% for the analytical scale mass load. The use of 3.5 μm nonporous particles improves the speed, sensitivity, and efficiency of analytical Protein A chromatography, making it applicable to high-throughput bioprocess monitoring.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Antibodies, MonoclonalStaphylococcal Protein AChromatography, AffinityPorosityChromatography, High Pressure LiquidParticle SizeAnimals

Substanzen

Antibodies, MonoclonalStaphylococcal Protein A

Autor:innen und Institutionen

  • Waters Corporation, 34 Maple Street, Milford, Massachusetts 01757, USA.

ORCID-Profile: Beatrice Muriithi, Fabrice Gritti

Zitieren

APA

Muriithi, B., Gritti, F., Gilar, M., Sarisozen, Y., Lauber, M., & Wyndham, K. (2025). High-Efficiency Analytical Protein A Columns for High Sensitivity Monoclonal Antibody Titer Analysis. Analytical Chemistry, 97(48), 26349-26356. https://doi.org/10.1021/acs.analchem.5c04766

Vancouver

Muriithi B, Gritti F, Gilar M, Sarisozen Y, Lauber M, Wyndham K. High-Efficiency Analytical Protein A Columns for High Sensitivity Monoclonal Antibody Titer Analysis. Analytical Chemistry. 2025;97(48):26349-26356. doi:10.1021/acs.analchem.5c04766

BibTeX
@article{Muriithi2025,
  author = {Muriithi, Beatrice and Gritti, Fabrice and Gilar, Martin and Sarisozen, Yeliz and Lauber, Matthew and Wyndham, Kevin},
  title = {High-Efficiency Analytical Protein A Columns for High Sensitivity Monoclonal Antibody Titer Analysis},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {48},
  pages = {26349--26356},
  doi = {10.1021/acs.analchem.5c04766}
}
Kostenlos starten →