EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Trapped Ion Mobility Improves Annotation Accuracy in LC-HRMS Screening Applications for Exposomics

Carolin Huber iD, Nadin Ulrich iD, Martin Krauss iD

Analytical Chemistry · 11.11.2025 · 97 (44) · 24608-24615

DOI: 10.1021/acs.analchem.5c04665 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 31.10.2025. Verfasst von Carolin Huber und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Exposure Science, Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, Leipzig 04318, Germany. Hauptthemen laut MEDLINE: Ion Mobility Spectrometry, Environmental Pollutants. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Ion mobility techniques coupled to mass spectrometry, such as trapped ion mobility (TIMS), are promoted to separate analytes from coeluting matrix interferences and to resolve isomers based on their corresponding CCS values. Complementary to the retention time (RT) dimension revealed from liquid chromatography, the collision cross section (CCS) serves as a robust and matrix-independent parameter. We evaluated the advantages of TIMS in the screening of human samples, such as urine, serum, breastmilk, and matrices relevant for exposure analysis, such as dust and wastewater. We conducted a screening library for 769 environmental contaminants, which resulted in a total of 948 CCS values (594 positive and 354 negative ionization modes). We screened for the potential co-occurrence of interfering compounds originating from five different matrix backgrounds, leading to peaks with similar m/z and RT but differences in the mobilograms. For all matrices combined, 112 peaks with different mobility values relative to the reference standard were found. Our evaluation highlights the benefits of TIMS in reducing the number of inconclusive assignments through the separation of coeluting compounds and background noise and gaining a high MS2 coverage for low-abundant ions. These advantages are beneficial especially for suspect screening applications, where broader RT windows are necessary.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ion Mobility SpectrometryEnvironmental PollutantsHumansChromatography, LiquidMass SpectrometryMilk, Human

Substanzen

Environmental Pollutants

Autor:innen und Institutionen

  • Department of Exposure Science, Helmholtz Centre for Environmental Research - UFZ, Permoserstr. 15, Leipzig 04318, Germany.

ORCID-Profile: Carolin Huber, Nadin Ulrich, Martin Krauss

Zitieren

APA

Huber, C., Ulrich, N., & Krauss, M. (2025). Trapped Ion Mobility Improves Annotation Accuracy in LC-HRMS Screening Applications for Exposomics. Analytical Chemistry, 97(44), 24608-24615. https://doi.org/10.1021/acs.analchem.5c04665

Vancouver

Huber C, Ulrich N, Krauss M. Trapped Ion Mobility Improves Annotation Accuracy in LC-HRMS Screening Applications for Exposomics. Analytical Chemistry. 2025;97(44):24608-24615. doi:10.1021/acs.analchem.5c04665

BibTeX
@article{Huber2025,
  author = {Huber, Carolin and Ulrich, Nadin and Krauss, Martin},
  title = {Trapped Ion Mobility Improves Annotation Accuracy in LC-HRMS Screening Applications for Exposomics},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {44},
  pages = {24608--24615},
  doi = {10.1021/acs.analchem.5c04665}
}
Kostenlos starten →