Rapid and Sensitive Fluorometric Quantification of Black Carbon in Biological Fluids
Analytical Chemistry · 2025
DOI: 10.1021/acs.analchem.5c03946 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Zhao Shu und 10 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beiji…. Hauptthemen laut MEDLINE: Fluorometry, Soot. Die Arbeit nennt 62 Literaturangaben. Gefördert von: National Key Research and Development Program of China, National Natural Science Foundation of China, Chinese Academy of Sciences Project for Young Scientists in Basic Research.
Abstract (Originalsprache)
The increase in wildfire frequency worldwide has contributed to persistent atmospheric black carbon (BC) pollution, which was closely relative to multiple adverse health effects. Accurate quantification of BC in biological tissues and fluids is fundamental for evaluating its health effect; however, existing analytical methodologies are hindered by time-consuming protocols, low throughput, and the need for expensive instrumental infrastructure. In this study, we developed a fluorometric method for quantifying BC in various biological fluids with the advantages of simplicity, high sensitivity, and low cost. Specifically, this technique enables quantification of five distinct types of BC across diverse biological liquids with a detection limit (LOD) of 0.23-7.57 mg/L. The method's LOD is comparable to the established advanced techniques for BC quantification (e.g., femtosecond illumination technique and laser desorption/ionization mass spectrometry) but avoids the use of expensive instruments. Compared with conventional ultraviolet-visible (UV-Vis) spectrophotometry, the fluorometric technique demonstrates higher accuracy and less interference from proteins, water-soluble ions, or suspended particles. The practicability of the method was examined through the A549 cell-based toxicological assays. The biologically effective exposure dose (BED, a parameter for evaluating the actual exposure dose of chemicals) of BC to A549 cells was determined to be approximately 30 pg/cell, which overcame a fundamental measurement challenge regarding the BED of BC in cellular assays. Overall, the present method addresses a significant challenge in BC analysis, thus facilitating its accurate risk assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China.
- College of Resources and Environment, University of Chinese Academy of Sciences, Beijing 100049, China.
- Sino-Danish College, University of Chinese Academy of Sciences, Beijing 100049, China.
- Institute of Environment and Health, Jianghan University, Wuhan 430056, China.
ORCID-Profile: Yao Pei, Jihua Tan, Qian Liu, Guibin Jiang
Förderung
- National Key Research and Development Program of China
- National Natural Science Foundation of China
- Chinese Academy of Sciences Project for Young Scientists in Basic Research
- Major Project of Guangzhou National Laboratory
Zitieren
APA
Shu, Z., Yan, Z., Sun, H., Li, S., Zhu, Y., Pei, Y., Yu, H., Qin, J., Tan, J., Liu, Q., & Jiang, G. (2025). Rapid and Sensitive Fluorometric Quantification of Black Carbon in Biological Fluids. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c03946
Vancouver
Shu Z, Yan Z, Sun H, Li S, Zhu Y, Pei Y, et al. Rapid and Sensitive Fluorometric Quantification of Black Carbon in Biological Fluids. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.5c03946
BibTeX
@article{Shu2025,
author = {Shu, Zhao and Yan, Zidong and Sun, Honglei and Li, Si and Zhu, Yanhuan and Pei, Yao and Yu, Hao and Qin, Juanjuan and Tan, Jihua and Liu, Qian and Jiang, Guibin},
title = {Rapid and Sensitive Fluorometric Quantification of Black Carbon in Biological Fluids},
journal = {Analytical Chemistry},
year = {2025},
doi = {10.1021/acs.analchem.5c03946}
}
EUVIMED