EUVIMEDEUVIMED entdecken
Crossref

Optimized Tangential Flow Filtration for Efficient Isolation of Highly Pure and Bioactive sEVs

Lei Luo iD, Yuhang Du, Xin Niu, Jiashuo Liu, Ji Yuan, Hong Xu iD, Yang Wang, Haiyan Li iD, Qing Li

Analytical Chemistry · 12.08.2025 · 97 (31) · 17261-17274

DOI: 10.1021/acs.analchem.5c03781 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 01.08.2025. Verfasst von Lei Luo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Microsurgery on Extremities, Department of Orthopedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong Univers…. Hauptthemen laut MEDLINE: Filtration, Extracellular Vesicles. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 65 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Science and Technology Commission of Shanghai Municipality, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Small extracellular vesicles (sEVs) have demonstrated significant therapeutic potential. However, the lack of efficient and scalable methods for sEV separation remains a critical barrier to their large-scale production as therapeutic agents. Tangential flow filtration (TFF) has emerged as a promising technique for large-scale sEV separation, but the absence of comprehensive and systematic studies makes it challenging to determine optimal TFF parameters for sEV isolation. In this study, we investigated the effects of key TFF parameters, including shear stress, molecular weight cutoff (MWCO), transmembrane pressure (TMP), and washing-filtration cycles, on sEVs separation and impurity removal. We evaluated particle concentration, size distribution, morphology, chemical properties, fluorescence, and protein content to assess the impact of these parameters. The results revealed that excessive shear stress (>9.05 Pa) during TFF led to protein aggregation and sEV damage. Using a filter membrane with an MWCO of 750 kDa and maintaining TMP between 3 and 5 psi prevented sEV leakage and achieved moderately high filtration efficiency. Based on these findings, optimal TFF parameters were identified. sEVs isolated using optimized TFF conditions (TFF-sEVs) were then compared with sEVs isolated via ultracentrifugation (UC-sEVs). TFF-sEVs exhibited comparable physical properties and purity to UC-sEVs but demonstrated superior proliferation-promoting activity and a 3-fold higher recovery rate. Quantitative proteomic analysis revealed that TFF-sEVs were enriched with extracellular vesicle membrane proteins and corona proteins, contributing to their enhanced bioactivity. In summary, optimizing TFF parameters enables efficient purification of sEVs, balancing purity, recovery, and bioactivity, paving the way for scalable production of sEVs and accelerating the clinical translation of sEV-based therapeutics.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

FiltrationExtracellular VesiclesHumansParticle SizeAnimals

Autor:innen und Institutionen

  • Institute of Microsurgery on Extremities, Department of Orthopedic Surgery, Shanghai Sixth People's Hospital Affiliated to Shanghai Jiao Tong University School of Medicine, Shanghai Jiao Tong University, 600 Yishan Road…
  • School of Biomedical Engineering, Shanghai Jiao Tong University, 1954 Huashan Road, Shanghai 200030, China.
  • Biomedical Engineering Department, School of Engineering, RMIT University, 124 La Trobe Street, Melbourne, Victoria 3001, Australia.

ORCID-Profile: Lei Luo, Hong Xu, Haiyan Li

Förderung

  • National Key Research and Development Program of China
  • Science and Technology Commission of Shanghai Municipality
  • National Natural Science Foundation of China
  • Interdisciplinary Program of Shanghai Jiao Tong University
  • State Key Laboratory of Drug Regulatory Science

Zitieren

APA

Luo, L., Du, Y., Niu, X., Liu, J., Yuan, J., Xu, H., Wang, Y., Li, H., & Li, Q. (2025). Optimized Tangential Flow Filtration for Efficient Isolation of Highly Pure and Bioactive sEVs. Analytical Chemistry, 97(31), 17261-17274. https://doi.org/10.1021/acs.analchem.5c03781

Vancouver

Luo L, Du Y, Niu X, Liu J, Yuan J, Xu H, et al. Optimized Tangential Flow Filtration for Efficient Isolation of Highly Pure and Bioactive sEVs. Analytical Chemistry. 2025;97(31):17261-17274. doi:10.1021/acs.analchem.5c03781

BibTeX
@article{Luo2025,
  author = {Luo, Lei and Du, Yuhang and Niu, Xin and Liu, Jiashuo and Yuan, Ji and Xu, Hong and Wang, Yang and Li, Haiyan and Li, Qing},
  title = {Optimized Tangential Flow Filtration for Efficient Isolation of Highly Pure and Bioactive sEVs},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {31},
  pages = {17261--17274},
  doi = {10.1021/acs.analchem.5c03781}
}
Kostenlos starten →