Multifunctional Co 3 O 4 @PDA Nanocomposite-Based Sensitive Dual-Mode Lateral Flow Immunoassay for the Simultaneous Detection of Two Antibodies against Respiratory Tract Pathogens
Analytical Chemistry · 30.09.2025 · 97 (38) · 20950-20961
DOI: 10.1021/acs.analchem.5c03616 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 15.09.2025. Verfasst von Tao Dong und 4 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Chemical Biology and Biosensing, College of Life Sciences, Qingdao University, Qingdao 266071, China. Hauptthemen laut MEDLINE: Nanocomposites, Cobalt, Mycoplasma pneumoniae, Indoles. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 50 Literaturangaben. Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Acute respiratory infections (ARIs) are among the leading causes of morbidity and mortality worldwide, with Mycoplasma pneumoniae (M. pneumoniae) and Chlamydia pneumoniae (C. pneumoniae) being major pathogens responsible for community-acquired respiratory infections. Rapid and accurate diagnosis is critical for improving patient outcomes and effectively controlling disease transmission. Herein, we report a novel dual-channel lateral flow immunoassay (DC-LFIA) platform based on the Co3O4@polydopamine (PDA) nanocomposite with outstanding extinction coefficient, oxidase-like activity, and magnetic properties for the simultaneous detection of specific IgM antibodies (Ab) against these two pathogens in human serum. The magnetic properties of the Co3O4@PDA nanocomposite enable rapid enrichment of trace target Abs from large-volume serum samples, with a high extinction coefficient for direct colorimetric visualization and an excellent oxidase-like catalytic activity for signal enhancement. On the basis of the multifunctional Co3O4@PDA nanocomposite, rapid dual-mode detection of serum Abs was achieved within 12 min. By the direct colorimetric mode, the visual limit of detection (vLOD) for M. pneumoniae Ab and C. pneumoniae Ab reached 2 and 1 ng/mL, respectively, while the oxidase-like catalyzing signal amplification mode further lowered the vLODs to 0.2 and 0.1 ng/mL, accordingly. Additionally, the signal normalization using a 3D-printed device significantly enhanced assay accuracy and reproducibility. When applied to 96 clinical serum samples, compared to commercial kits, this multifunctional Co3O4@PDA-based DC-LFIA demonstrated superior performance, providing a reliable approach for simultaneous antibody detection in respiratory infection diagnosis. Overall, this work contributes a valuable diagnostic tool to the field of rapid detection of ARIs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Institute for Chemical Biology and Biosensing, College of Life Sciences, Qingdao University, Qingdao 266071, China.
- School of Public Health, Anhui University of Science and Technology, Hefei 231131, China.
- Qingdao Hightop Biotech Co., Ltd, 369 Hedong Road, Hi-tech Industrial Development Zone, Qingdao 266112, China.
- Collaborative Innovation Center for Nanomaterials & Optoelectronic Devices, College of Physics, Qingdao University, Qingdao 266071, China.
ORCID-Profile: Aihua Liu
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Dong, T., Sun, G., Liu, W., Long, Y., & Liu, A. (2025). Multifunctional Co 3 O 4 @PDA Nanocomposite-Based Sensitive Dual-Mode Lateral Flow Immunoassay for the Simultaneous Detection of Two Antibodies against Respiratory Tract Pathogens. Analytical Chemistry, 97(38), 20950-20961. https://doi.org/10.1021/acs.analchem.5c03616
Vancouver
Dong T, Sun G, Liu W, Long Y, Liu A. Multifunctional Co 3 O 4 @PDA Nanocomposite-Based Sensitive Dual-Mode Lateral Flow Immunoassay for the Simultaneous Detection of Two Antibodies against Respiratory Tract Pathogens. Analytical Chemistry. 2025;97(38):20950-20961. doi:10.1021/acs.analchem.5c03616
BibTeX
@article{Dong2025,
author = {Dong, Tao and Sun, Guangze and Liu, Wanjian and Long, Yunze and Liu, Aihua},
title = {Multifunctional Co 3 O 4 @PDA Nanocomposite-Based Sensitive Dual-Mode Lateral Flow Immunoassay for the Simultaneous Detection of Two Antibodies against Respiratory Tract Pathogens},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {38},
pages = {20950--20961},
doi = {10.1021/acs.analchem.5c03616}
}
EUVIMED