EUVIMEDEUVIMED entdecken
Crossref

Scaling Peptide-Barcode Approach for Parallel Evaluation of Protein Expression from Multiple mRNA Variants

Shun Kumano iD, Kazuki Tanaka, Shoko Kawakami, Mariko Yamamoto, Rena Akahori, Akihiro Nojima

Analytical Chemistry · 2026

DOI: 10.1021/acs.analchem.5c02991 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2026. Verfasst von Shun Kumano und 5 weiteren Autor:innen. Beteiligte Einrichtung: Research & Development Group, Hitachi, Ltd., Tokyo 185-8601, Japan. Hauptthemen laut MEDLINE: RNA, Messenger, Green Fluorescent Proteins, Peptides. Die Arbeit nennt 31 Literaturangaben. Gefördert von: Hitachi, ARCALIS, Inc..

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Messenger RNA (mRNA) technology has revolutionized therapeutic design, yet optimizing untranslated regions (UTRs) and synonymous codons still depends on low-throughput, trial-and-error workflows. We previously reported a peptide-barcode method that quantifies protein expression from pooled mRNAs, but only two variants were tested. For this study, we extend the approach to nine mRNA variants produced by combining three different 5' UTRs with three codon-modified enhanced green fluorescent protein (eGFP) coding sequences. All nine template plasmids were assembled in a single Gibson reaction, transcribed together, and cotransfected into HEK293T cells. At least five distinct ten-residue peptide barcodes were assigned to each mRNA variant in the pooled library. After translation, the barcodes were enzymatically released and analyzed in a single liquid chromatography-mass spectrometry (LC-MS) run. To correct for differences in transcript abundance within the pool, the LC-MS signals were normalized to the corresponding barcode read counts obtained by nanopore sequencing of the same pooled mRNA library. Averaging the barcode signals assigned to each variant partially reduced barcode-specific bias and yielded a moderate correlation coefficient of 0.53 relative to the eGFP fluorescence measured from nine separate single-transfection controls. While not intended for precise quantification, the results indicate that peptide barcoding can discriminate variants with higher protein output within a single pooled experiment and is useful for first-pass, rank-order screening. Thus, this peptide-barcode method provides a scalable route toward higher-throughput optimization of larger mRNA libraries.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RNA, MessengerGreen Fluorescent ProteinsPeptidesHumansHEK293 CellsChromatography, LiquidMass Spectrometry

Substanzen

RNA, MessengerGreen Fluorescent Proteinsenhanced green fluorescent proteinPeptides

Autor:innen und Institutionen

  • Research & Development Group, Hitachi, Ltd., Tokyo 185-8601, Japan.
  • Dept. Development ARCALIS, Inc., Chiba 277-0871, Japan.

ORCID-Profile: Shun Kumano

Förderung

  • Hitachi
  • ARCALIS, Inc.

Zitieren

APA

Kumano, S., Tanaka, K., Kawakami, S., Yamamoto, M., Akahori, R., & Nojima, A. (2026). Scaling Peptide-Barcode Approach for Parallel Evaluation of Protein Expression from Multiple mRNA Variants. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c02991

Vancouver

Kumano S, Tanaka K, Kawakami S, Yamamoto M, Akahori R, Nojima A. Scaling Peptide-Barcode Approach for Parallel Evaluation of Protein Expression from Multiple mRNA Variants. Analytical Chemistry. 2026. doi:10.1021/acs.analchem.5c02991

BibTeX
@article{Kumano2026,
  author = {Kumano, Shun and Tanaka, Kazuki and Kawakami, Shoko and Yamamoto, Mariko and Akahori, Rena and Nojima, Akihiro},
  title = {Scaling Peptide-Barcode Approach for Parallel Evaluation of Protein Expression from Multiple mRNA Variants},
  journal = {Analytical Chemistry},
  year = {2026},
  doi = {10.1021/acs.analchem.5c02991}
}
Kostenlos starten →