Rapid Heavy Metals Detection Using LIBS with Concentration Gradient Generators
Analytical Chemistry · 05.08.2025 · 97 (30) · 16403-16410
DOI: 10.1021/acs.analchem.5c02125 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 28.07.2025. Verfasst von Xinrui Pan und 6 weiteren Autor:innen. Beteiligte Einrichtung: Wuhan National Laboratory for Optoelectronics (WNLO), Huazhong University of Science and Technology, Wuhan, Hubei 430074, China. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 40 Literaturangaben. Gefördert von: Shanxi Provincial Education Department, National Key Research and Development Program of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Surface water, a critical global freshwater resource, faces severe heavy metal contamination threatening ecosystems and human health. Traditional detection methods like ICP-MS are time-consuming and expensive due to complex sample preparation, which is not practical for on-site monitoring. While laser-induced breakdown spectroscopy (LIBS) enables rapid and in situ elemental analysis, its quantitative efficiency in on-site monitoring remains limited by the laborious manual gradient-preparing procedures. Here, we developed a microfluidic-based concentration gradient generator (CGG)-LIBS platform by integrating automated gradient generation with standard addition calibration to enable real-time field quantification of heavy metals in water. The microfluidic CGG device, fabricated via 3D printing, generated six linear concentration gradients (R2 > 0.998) through continuous injection mixing. This method integrates multiple steps of solution preparation into a single process, thereby simplifying the experimental procedure while minimizing errors and contamination associated with segmented operations. The trace heavy metals barium (Ba), copper (Cu), and manganese (Mn) were tested using CGG-LIBS, where the results (Ba: R2 = 0.999, LoD = 40.9 μg/L; Cu: R2 = 0.998, LoD = 71.1 μg/L; Mn: R2 = 0.999, LoD = 62.8 μg/L) demonstrated the stable, accurate, and sensitive quantitative determination performance of CGG-LIBS. And the LoDs meet the standard limit of China (GB 3838-2002). Furthermore, comparisons with ICP-MS (
Autor:innen und Institutionen
- Wuhan National Laboratory for Optoelectronics (WNLO), Huazhong University of Science and Technology, Wuhan, Hubei 430074, China.
- Department of Physics, City University of Hong Kong, Kowloon, Hong Kong Special Administrative Region 999077, China.
- Jiangxi Provincial Institute of State-owned Capital and Modern Industry Innovative Development, Nanchang, Jiangxi 330025, China.
- College of Life Science, Shanxi Agricultural University, Taigu, Shanxi 030801, China.
ORCID-Profile: Yuanchao Liu, Shaofei Shen, Lianbo Guo
Förderung
- Shanxi Provincial Education Department
- National Key Research and Development Program of China
- National Natural Science Foundation of China
Zitieren
APA
Pan, X., Liu, Y., Wang, W., Zhang, F., Hu, X., Shen, S., & Guo, L. (2025). Rapid Heavy Metals Detection Using LIBS with Concentration Gradient Generators. Analytical Chemistry, 97(30), 16403-16410. https://doi.org/10.1021/acs.analchem.5c02125
Vancouver
Pan X, Liu Y, Wang W, Zhang F, Hu X, Shen S, et al. Rapid Heavy Metals Detection Using LIBS with Concentration Gradient Generators. Analytical Chemistry. 2025;97(30):16403-16410. doi:10.1021/acs.analchem.5c02125
BibTeX
@article{Pan2025,
author = {Pan, Xinrui and Liu, Yuanchao and Wang, Weiliang and Zhang, Furong and Hu, Xiujuan and Shen, Shaofei and Guo, Lianbo},
title = {Rapid Heavy Metals Detection Using LIBS with Concentration Gradient Generators},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {30},
pages = {16403--16410},
doi = {10.1021/acs.analchem.5c02125}
}
EUVIMED