Rapid Fluorescence Lifetime Imaging through One-Dimensional Deep Learning Optimization
Analytical Chemistry · 22.07.2025 · 97 (28) · 15262-15273
DOI: 10.1021/acs.analchem.5c01984 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 11.07.2025. Verfasst von Xinwei Gao und 9 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Radio Frequency Heterogeneous Integration (Shenzhen University); College of Physics and Optoelectronic Engineering, Key Labor…. Hauptthemen laut MEDLINE: Deep Learning, Optical Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Science and Technology Foundation of Shenzhen City, Basic and Applied Basic Research Foundation of Guangdong Province.
Abstract (Originalsprache)
Traditional fluorescence lifetime imaging (FLIM) provides valuable quantitative insights for biomedical and molecular biology research, but often relies on computationally intensive datafitting methods to extract meaningful metrics. To address this limitation, we propose a hardware-efficient deep learning approach using one-dimensional channel attention convolutional neural networks (1D CANNs) to process FLIM data with high efficiency and speed. The 1D CANN offers several advantages, including reduced computational requirements, the ability to train on smaller datasets, and minimal training times. The superior performance of 1D CANNs in fluorescence lifetime fitting has been validated by using raw time-correlated single-photon counting (TCSPC) data. By utilizing an experimental training dataset, we achieved strong consistency between the predicted lifetime maps of dynamic fluorescence imaging and the ground truth. Moreover, we extended the application of 1D CANNs to phosphorescence lifetime imaging (PLIM), achieving a prediction error within 10%. Beyond fluorescence lifetime fitting, we demonstrated the versatility of 1D CANNs by integrating them with FLIRR (Fluorescence-Lifetime Redox Ratio) to diagnose Alzheimer's disease in mouse brain slices. Additionally, we applied 1D CANNs to STED-FLIM imaging, achieving improved spatial resolution. Our findings highlight the broad potential of 1D CANNs in biomedical and photonics applications, demonstrating their robustness across varying photon count conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- State Key Laboratory of Radio Frequency Heterogeneous Integration (Shenzhen University); College of Physics and Optoelectronic Engineering, Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education a…
ORCID-Profile: Luwei Wang, Wei Yan, Liwei Liu
Förderung
- National Key Research and Development Program of China
- Science and Technology Foundation of Shenzhen City
- Basic and Applied Basic Research Foundation of Guangdong Province
- China Postdoctoral Science Foundation
- Department of Education of Guangdong Province
- National Natural Science Foundation of China
- Shenzhen University
- Shenzhen Key Laboratory of Photonics and Biophotonics
Zitieren
APA
Gao, X., Liu, Y., Guo, Y., Wang, L., Zhu, Y., Xu, L., Weng, X., Yan, W., Liu, L., & Qu, J. (2025). Rapid Fluorescence Lifetime Imaging through One-Dimensional Deep Learning Optimization. Analytical Chemistry, 97(28), 15262-15273. https://doi.org/10.1021/acs.analchem.5c01984
Vancouver
Gao X, Liu Y, Guo Y, Wang L, Zhu Y, Xu L, et al. Rapid Fluorescence Lifetime Imaging through One-Dimensional Deep Learning Optimization. Analytical Chemistry. 2025;97(28):15262-15273. doi:10.1021/acs.analchem.5c01984
BibTeX
@article{Gao2025,
author = {Gao, Xinwei and Liu, Yanfeng and Guo, Yong and Wang, Luwei and Zhu, Yinru and Xu, Lukui and Weng, Xiaoyu and Yan, Wei and Liu, Liwei and Qu, Junle},
title = {Rapid Fluorescence Lifetime Imaging through One-Dimensional Deep Learning Optimization},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {28},
pages = {15262--15273},
doi = {10.1021/acs.analchem.5c01984}
}
EUVIMED