Ultrasensitive Quantum Weak Measurement Biochemical Sensor via a Porous Anodic Alumina Nanostructure
Analytical Chemistry · 2025
DOI: 10.1021/acs.analchem.5c01860 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Jiao Ren und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei 230009, Anhui, China. Hauptthemen laut MEDLINE: Aluminum Oxide, Biosensing Techniques, Serum Albumin, Bovine, Nanostructures. Die Arbeit nennt 32 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China, Natural Science Foundation of Anhui Province.
Abstract (Originalsprache)
In this paper, an ultrasensitive quantum weak measurement biochemical sensor based on porous anodic alumina (PAA) was first proposed and realized. The PAA film has the advantages of a regular hexagonal arrangement of pores, a high specific surface area, and low cost, which is a significant biosensing platform. By optimizing the structure parameters such as pore size and thickness of the PAA film, the biochemical sensor achieves a refractive index sensitivity of as high as 25 326 nm/RIU with a corresponding resolution of as low as 1.4 × 10-7 RIU. The combination of the PAA film and weak measurement technology amplifies the sensing changes of small phase differences, thus realizing a highly sensitive response to the changes of the sensing medium. The biochemical sensor is capable of detecting biomolecules, such as glucose and proteins, with low detection limits and high specificity. Molecular testing validates that the sensor has a limit of detection as low as 3.9 mg/L for glucose small molecules and 112 pM for bovine serum albumin (BSA) biomacromolecules. The specificity testing validates that the biosensor is capable of specifically recognizing IgG proteins with high sensitivity, and a limit of detection as low as 8.4 ng/mL was achieved. As a result, the proposed PAA-based reflection-type quantum weak measurement biochemical sensor has the advantages of robustness and simplicity of structure, providing a versatile platform for the next generation of high-sensitivity biochemical sensing technology.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- School of Instrument Science and Optoelectronics Engineering, Hefei University of Technology, Hefei 230009, Anhui, China.
- Anhui Province Key Laboratory of Measuring Theory and Precision Instrument, Hefei University of Technology, Hefei 230009, Anhui, China.
ORCID-Profile: Guiqiang Wang
Förderung
- Fundamental Research Funds for the Central Universities
- National Natural Science Foundation of China
- Natural Science Foundation of Anhui Province
Zitieren
APA
Ren, J., Sun, M., Qin, Q., Ma, C., Xie, P., Xu, X., & Wang, G. (2025). Ultrasensitive Quantum Weak Measurement Biochemical Sensor via a Porous Anodic Alumina Nanostructure. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c01860
Vancouver
Ren J, Sun M, Qin Q, Ma C, Xie P, Xu X, et al. Ultrasensitive Quantum Weak Measurement Biochemical Sensor via a Porous Anodic Alumina Nanostructure. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.5c01860
BibTeX
@article{Ren2025,
author = {Ren, Jiao and Sun, Mengyao and Qin, Qin and Ma, Changwei and Xie, Pengpeng and Xu, Xiaoxue and Wang, Guiqiang},
title = {Ultrasensitive Quantum Weak Measurement Biochemical Sensor via a Porous Anodic Alumina Nanostructure},
journal = {Analytical Chemistry},
year = {2025},
doi = {10.1021/acs.analchem.5c01860}
}