Scanning Electrochemical Cell Microscopy (SECCM) with Hydrogel Probes: A Theoretical and Experimental Investigation
Analytical Chemistry · 16.09.2025 · 97 (36) · 19472-19479
DOI: 10.1021/acs.analchem.5c01729 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 29.08.2025. Verfasst von Qiangqiang Zheng und 4 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, P. R. China. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: Natural Science Foundation of Sichuan Province, Science and Technology Department of Sichuan Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
Scanning Electrochemical Cell Microscopy (SECCM) has emerged as a powerful tool in electrochemical research due to its ability to measure morphology and electrochemical information simultaneously at the nano- or microscale. However, traditional SECCM using liquid probes suffers from issues, such as evaporation, solution residue, and droplet deformation. This study introduced a hydrogel-based SECCM probe and comprehensively explored its superiority over liquid probes through both theoretical and experimental approaches. Finite element simulations demonstrated that hydrogel probes significantly reduce the contact area with samples and minimize the retraction distance. These effects are attributed to the restriction of the solution flow by the hydrogel's 3D network structures. SECCM experimental results further confirmed the superior stability and efficiency of the hydrogel probes in imaging applications. In addition, the hydrogel probe was successfully applied to characterize Au/ITO interfaces, enabling the concurrent acquisition of localized morphological and electrochemical information, thereby demonstrating its feasibility for standard SECCM measurements. These findings provide a valuable reference for the emerging field of hydrogel probes in SECCM research and development.
Autor:innen und Institutionen
- Key Laboratory of Education Ministry for Modern Design Rotor-Bearing System, Xi'an Jiaotong University, Xi'an 710049, P. R. China.
- School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an 710049, P. R. China.
- Department of Biophysics, School of Basic Medical Sciences, Health Science Center, Xi'an Jiaotong University, Xi'an, 710061, China.
- Institute of Medical Engineering, Translational Medicine Institute, Xi'an Jiaotong University, Xi'an 710061, China.
- Key Laboratory of Testing Technology for Manufacturing Process, Ministry of Education, Southwest University of Science and Technology, Mianyang 621010, P. R. China.
ORCID-Profile: Qiangqiang Zheng, Jian Zhuang, Jian Wang, Xiaobo Liao
Förderung
- Natural Science Foundation of Sichuan Province
- Science and Technology Department of Sichuan Province
- National Natural Science Foundation of China
Zitieren
APA
Zheng, Q., Zhuang, J., Wang, J., Liao, X., & Meng, Y. (2025). Scanning Electrochemical Cell Microscopy (SECCM) with Hydrogel Probes: A Theoretical and Experimental Investigation. Analytical Chemistry, 97(36), 19472-19479. https://doi.org/10.1021/acs.analchem.5c01729
Vancouver
Zheng Q, Zhuang J, Wang J, Liao X, Meng Y. Scanning Electrochemical Cell Microscopy (SECCM) with Hydrogel Probes: A Theoretical and Experimental Investigation. Analytical Chemistry. 2025;97(36):19472-19479. doi:10.1021/acs.analchem.5c01729
BibTeX
@article{Zheng2025,
author = {Zheng, Qiangqiang and Zhuang, Jian and Wang, Jian and Liao, Xiaobo and Meng, Yao},
title = {Scanning Electrochemical Cell Microscopy (SECCM) with Hydrogel Probes: A Theoretical and Experimental Investigation},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {36},
pages = {19472--19479},
doi = {10.1021/acs.analchem.5c01729}
}