EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Evaluation of Three Sample Preparation Methods for LC-HRMS Suspect Screening of Contaminants of Emerging Concern in Effluent Wastewater

Dana Orlando-Véliz, Rocío Inés Bonansea, Manuel García-Vara, Varvara Nikolopoulou iD, Miren López de Alda iD

Analytical Chemistry · 02.12.2025 · 97 (47) · 25946-25957

DOI: 10.1021/acs.analchem.5c01659 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 19.11.2025. Verfasst von Dana Orlando-Véliz und 4 weiteren Autor:innen. Beteiligte Einrichtung: Water, Environmental and Food Chemistry Research Unit, Dep. of Environmental Chemistry, IDAEA-CSIC, Institute for Environmental Assessment and Water …. Hauptthemen laut MEDLINE: Wastewater, Water Pollutants, Chemical. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Commission, Ministerio de Econom??a y Competitividad, Generalitat de Catalunya.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Suspect screening is a valuable tool for studying the pollution footprint of environmental samples, but the sample preparation (SP) method significantly affects the results. In this study, three SP methods─lyophilization, direct injection, and online solid-phase extraction (SPE)─were evaluated for suspect screening of contaminants of emerging concern (CECs) in effluent wastewater using liquid chromatography-high resolution mass spectrometry (LC-HRMS). LC-HRMS was performed with a Q-ToF mass analyzer in both positive and negative electrospray ionization modes, and pollutants were identified using the NORMAN SusDat database. A total of 119 CECs were identified with high confidence (all above level 2a). Of these, 115 were detected using lyophilization, 37 with direct injection, and 49 with online SPE. Principal component analysis revealed distinct patterns for each SP method. In all cases, the pollution profile was dominated by pharmaceuticals, followed by industrial chemicals. Articaine, a local anesthetic previously unreported in the aquatic environment, was the most abundant compound found. Industrial chemicals included phthalates, flame retardants, benzotriazoles, and perfluoroalkyl substances, among others. The remaining identified CECs were personal care products, pesticides, and drugs of abuse. Compound prioritization, based on abundance, persistence, mobility, bioaccumulation potential, and toxicity, identified the antibiotics clindamycin and tiamulin, the analgesic flufenamic acid, the musk fragrance metabolite galaxolidone, and the antidepressant venlafaxine metabolite, O-desmethyl venlafaxine, as top priority. These results highlight the importance of applying an appropriate SP method to obtain a comprehensive CEC footprint in suspect screening analysis and demonstrate the suitability of lyophilization for wastewater characterization.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WastewaterWater Pollutants, ChemicalChromatography, LiquidSolid Phase ExtractionMass Spectrometry

Substanzen

WastewaterWater Pollutants, Chemical

Autor:innen und Institutionen

  • Water, Environmental and Food Chemistry Research Unit, Dep. of Environmental Chemistry, IDAEA-CSIC, Institute for Environmental Assessment and Water Research (IDAEA-CSIC), C/Jordi Girona 18-26, 08034 Barcelona, Spain.
  • PhD student in the Analytical and Environmental Chemistry PhD Program at the University of Barcelona, C/Martí i Franquès, 1-11, Les Corts, 08028 Barcelona, Spain.
  • Department of Environmental Health Sciences, Yale School of Public Health, Yale University, New Haven, Connecticut 06510, United States.

ORCID-Profile: Varvara Nikolopoulou, Miren López de Alda

Förderung

  • European Commission
  • Ministerio de Econom??a y Competitividad
  • Generalitat de Catalunya

Zitieren

APA

Orlando-Véliz, D., Bonansea, R. I., García-Vara, M., Nikolopoulou, V., & López de Alda, M. (2025). Evaluation of Three Sample Preparation Methods for LC-HRMS Suspect Screening of Contaminants of Emerging Concern in Effluent Wastewater. Analytical Chemistry, 97(47), 25946-25957. https://doi.org/10.1021/acs.analchem.5c01659

Vancouver

Orlando-Véliz D, Bonansea RI, García-Vara M, Nikolopoulou V, López de Alda M. Evaluation of Three Sample Preparation Methods for LC-HRMS Suspect Screening of Contaminants of Emerging Concern in Effluent Wastewater. Analytical Chemistry. 2025;97(47):25946-25957. doi:10.1021/acs.analchem.5c01659

BibTeX
@article{OrlandoVliz2025,
  author = {Orlando-Véliz, Dana and Bonansea, Rocío Inés and García-Vara, Manuel and Nikolopoulou, Varvara and López de Alda, Miren},
  title = {Evaluation of Three Sample Preparation Methods for LC-HRMS Suspect Screening of Contaminants of Emerging Concern in Effluent Wastewater},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {47},
  pages = {25946--25957},
  doi = {10.1021/acs.analchem.5c01659}
}
Kostenlos starten →