EUVIMEDEUVIMED entdecken
Crossref

An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices

Tyler D Schlieder iD, Kirby P Hobbs iD, Amanda D French iD, Lee H Hughes, Isaac J Arnquist, Chelsie Beck iD

Analytical Chemistry · 17.06.2025 · 97 (23) · 12313-12320

DOI: 10.1021/acs.analchem.5c01397 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 04.06.2025. Verfasst von Tyler D Schlieder und 5 weiteren Autor:innen. Beteiligte Einrichtung: Pacific Northwest National Laboratory, Richland, Washington 99352, United States. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: Office of Defense Nuclear Nonproliferation, Pacific Northwest National Laboratory.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Accurate actinide measurements are critical within the field of nuclear science. Traditional methods for actinide quantification require time-consuming sample processing prior to analysis. There is a need for rapid analytical techniques that still maintain a high degree of accuracy. In this work, actinide reactivity was assessed for multiple oxygen-containing reaction gases using quadrupole inductively coupled plasma tandem mass spectrometry (Q-ICP-MS/MS) to evaluate actinide analysis in complex sample matrices without analyte-matrix separation. A novel method was developed to measure 241Am/241Pu in complex sample matrices using an O2/He reaction gas with no matrix removal or analyte preconcentration. This inline method reduces matrix-derived polyatomic interferences that complicate traditional ICP-MS analyses by mass-shifting to 241Am16O+ and 241Pu16O2+, allowing Am and Pu to be mass separated for simultaneous analysis. While mass shifting is efficient, a small portion of Am+ ( 1000 μg·g-1). Method detection limits of 15.9 and 9.6 fg·g-1 were determined for 241Am and 241Pu, respectively, and 241Am/241Pu ratios were measured with accuracies within

Autor:innen und Institutionen

  • Pacific Northwest National Laboratory, Richland, Washington 99352, United States.

ORCID-Profile: Tyler D Schlieder, Kirby P Hobbs, Amanda D French, Chelsie Beck

Förderung

  • Office of Defense Nuclear Nonproliferation
  • Pacific Northwest National Laboratory

Zitieren

APA

Schlieder, T. D., Hobbs, K. P., French, A. D., Hughes, L. H., Arnquist, I. J., & Beck, C. (2025). An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices. Analytical Chemistry, 97(23), 12313-12320. https://doi.org/10.1021/acs.analchem.5c01397

Vancouver

Schlieder TD, Hobbs KP, French AD, Hughes LH, Arnquist IJ, Beck C. An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices. Analytical Chemistry. 2025;97(23):12313-12320. doi:10.1021/acs.analchem.5c01397

BibTeX
@article{Schlieder2025,
  author = {Schlieder, Tyler D and Hobbs, Kirby P and French, Amanda D and Hughes, Lee H and Arnquist, Isaac J and Beck, Chelsie},
  title = {An Evaluation of Actinide Reactivity with CO 2 , O 2 , and O 2 /He Gases using Inductively Coupled Plasma Tandem Mass Spectrometry: Application to Simultaneous Measurement of 241 Am/ 241 Pu Ratios in Unseparated Complex Matrices},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {23},
  pages = {12313--12320},
  doi = {10.1021/acs.analchem.5c01397}
}
Kostenlos starten →