A Rapid Electrochemical DNA Biosensor for Serum Uric Acid Using the Pre-equilibrium Binding Mechanism
Analytical Chemistry · 2025
DOI: 10.1021/acs.analchem.5c01312 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Zhenglian Li und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Analytical Chemistry and Instrument for Life Science, The Key Laboratory of Biomedical Information Engineering of Ministry of Education,…. Hauptthemen laut MEDLINE: Uric Acid, Biosensing Techniques, Electrochemical Techniques, DNA. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 48 Literaturangaben. Gefördert von: National Key Research and Development Program of China, Key Research and Development Projects of Shaanxi Province.
Abstract (Originalsprache)
The precise and rapid detection of uric acid (UA) in human serum is pivotal for diagnosing and managing metabolic disorders such as gout, kidney disease, and hyperuricemia. However, current equilibrium-based assays suffer from long incubation time, interference from serum components, and a narrow dynamic range. Herein, we present a robust electrochemical DNA assay (EC-DNA) that can respond rapidly (within 1 min) to serum UA under pre-equilibrium conditions, with an extended dynamic range (1-1000 μM). Our assay employs a Mg2+-dependent UA aptamer that can form a metastable hairpin-like structure, allowing for rapid UA binding. The reaction mechanism was validated using electron transfer rate measurements, electrochemical melting experiments, and urea-induced denaturation assays. This pre-equilibrium approach minimizes nonspecific protein adsorption and signal decay, ensuring reliable detection in complex biofluids such as serum and saliva. Our sensor demonstrated a strong correlation with commercial colorimetric assays (Pearson r = 0.947) and successfully differentiated UA levels between healthy individuals and gout patients. Overall, our EC-DNA assay not only presents a rapid and robust method to detect UA in complex biological samples but also provides valuable insights into DNA binding assays under pre-equilibrium conditions.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Institute of Analytical Chemistry and Instrument for Life Science, The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi'an Jiaotong University, Xi'…
- The Huai'an Maternity and Child Clinical College of Xuzhou Medical University, Huai'an, Jiangsu 223002, P.R. China.
ORCID-Profile: Biwu Liu
Förderung
- National Key Research and Development Program of China
- Key Research and Development Projects of Shaanxi Province
Zitieren
APA
Li, Z., Gao, G., Lv, Y., Zhang, Y., Wang, H., & Liu, B. (2025). A Rapid Electrochemical DNA Biosensor for Serum Uric Acid Using the Pre-equilibrium Binding Mechanism. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c01312
Vancouver
Li Z, Gao G, Lv Y, Zhang Y, Wang H, Liu B. A Rapid Electrochemical DNA Biosensor for Serum Uric Acid Using the Pre-equilibrium Binding Mechanism. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.5c01312
BibTeX
@article{Li2025,
author = {Li, Zhenglian and Gao, Ge and Lv, Yanguan and Zhang, Yingjie and Wang, Haihui and Liu, Biwu},
title = {A Rapid Electrochemical DNA Biosensor for Serum Uric Acid Using the Pre-equilibrium Binding Mechanism},
journal = {Analytical Chemistry},
year = {2025},
doi = {10.1021/acs.analchem.5c01312}
}
EUVIMED