Real-Time Bacterial Monitoring and Drug Screening Using the Interdigitated Wave-Shaped Biosensor (IWE), Combined with FEM and Molecular Docking Studies
Analytical Chemistry · 2025
DOI: 10.1021/acs.analchem.5c01250 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Zeeshan und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, South Korea. Hauptthemen laut MEDLINE: Biosensing Techniques, Molecular Docking Simulation, Anti-Bacterial Agents, Staphylococcus aureus. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 47 Literaturangaben. Gefördert von: National Research Foundation of Korea, Korea Environmental Industry and Technology Institute.
Abstract (Originalsprache)
Rapid and accurate detection of bacteria in water, food, and air is essential for protecting public health, especially amid rising antimicrobial resistance and outbreaks. Traditional detection methods, while reliable, are time-consuming, resource-intensive, and unsuitable for real-time monitoring. Similarly, antibiotic efficacy assessment requires laborious culturing, delaying treatment. This study presents an interdigitated wave-shaped electrode (IWE) capacitance biosensor for real-time bacterial monitoring and drug evaluation. The IWE, optimized via COMSOL simulations addresses edge effects and enhances electric field uniformity and capacitance sensitivity. Simulated capacitance in PBS (5.21 × 10-7 F at 1 Hz) closely matched the experimental value (3.19 × 10-7 F at 1 Hz), validating the optimized IWE design. Integrated with a 16-channel multiplexer, the biosensor enabled high-throughput, real-time detection of Staphylococcus aureus, Bacillus cereus, and Escherichia coli over a range of 10 to 104 CFU/mL, with a detection limit of 10 CFU/mL. Molecular docking simulations were employed to assess antibiotics, which were subsequently tested through real-time capacitance measurements. A decrease in the capacitance indicated effective bacterial inhibition at concentrations exceeding the minimum inhibitory concentration. Results were further validated through disk diffusion assays and scanning electron microscopy, confirming the accuracy. This integrated approach demonstrates the biosensor's potential for real-time pathogen detection and antimicrobial susceptibility assessment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Electronic Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, South Korea.
- Department of Semiconductor Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, South Korea.
- Department of Health Science and Technology, Gachon University, Incheon 21999, South Korea.
ORCID-Profile: Zeeshan, Sungbo Cho
Förderung
- National Research Foundation of Korea
- Korea Environmental Industry and Technology Institute
Zitieren
APA
Zeeshan, & Cho, S. (2025). Real-Time Bacterial Monitoring and Drug Screening Using the Interdigitated Wave-Shaped Biosensor (IWE), Combined with FEM and Molecular Docking Studies. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c01250
Vancouver
Zeeshan, Cho S. Real-Time Bacterial Monitoring and Drug Screening Using the Interdigitated Wave-Shaped Biosensor (IWE), Combined with FEM and Molecular Docking Studies. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.5c01250
BibTeX
@article{Zeeshan2025,
author = {Zeeshan and Cho, Sungbo},
title = {Real-Time Bacterial Monitoring and Drug Screening Using the Interdigitated Wave-Shaped Biosensor (IWE), Combined with FEM and Molecular Docking Studies},
journal = {Analytical Chemistry},
year = {2025},
doi = {10.1021/acs.analchem.5c01250}
}
EUVIMED