EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

One-Drop Serum Screening Test to Monitor Tissue Iron Accumulation

Gabriely S Folli iD, Anne Louise S Torres iD, Matthews Martins iD, Luiz Ricardo Rodrigues Silva, Vinícius Bermond Marques, Maria Tereza Carneiro, Larissa Dias Roriz, Leonardo Dos Santos, Wanderson Romão iD, Francis L Martin iD, Paulo R Filgueiras iD, Valério G Barauna

Analytical Chemistry · 2025

DOI: 10.1021/acs.analchem.5c00778 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Gabriely S Folli und 11 weiteren Autor:innen. Beteiligte Einrichtung: Departamento of Chemistry, Federal University of Espírito Santo (UFES), Av. Fernando Ferrari, 514, Vitória, Espírito Santo 29075-910, Brazil. Hauptthemen laut MEDLINE: Iron, Iron Overload. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Funda??o de Amparo ? Pesquisa e Inova??o do Esp?rito Santo, Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico, Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Although iron is an essential element for vital body functions, iron overload (IO) is accompanied by significant cellular damage due to its accumulation within organs. Thus, early diagnosis and accurate identification of the affected organs are critical for preventing irreversible damage and improving patient survival rates. Diagnosing tissue iron deposits relieves invasive biopsies with atomic absorption spectrometry (reserved for specific cases) or noninvasive but costly and time-consuming imaging techniques like computerized tomography and magnetic resonance, which provide limited analytical data and are unsuitable for routine screening. As an alternative, Fourier transform infrared spectroscopy combined with machine learning has emerged as a promising approach for supporting medical decision-making. In this study, we developed a minimally invasive method to identify IO and quantify iron levels in blood and tissues (heart, liver, spleen, and kidney) without biopsies. PLS-DA classification models and PLS regression models were constructed based on samples categorized into a control group (n = 10) and three iron-administered groups at 250 mg kg-1 (n = 14), 500 mg·kg-1 (n = 13), and 1000 mg·kg-1 (n = 15). Iron levels were measured in blood samples and tissue biopsies (spleen, heart, liver, and kidney). The binary classification models (control vs iron-administered) and multiclass models (control, 250, 500, and 1000 mg·kg-1) demonstrated satisfactory performance into train and validation groups. PLS regression models for quantifying iron concentrations in blood and tissues exhibited excellent linearity and low associated errors across both calibration and test groups. Permutation tests confirmed that all models found a real class structure in the data, were not random, and were built using true chemical information. The chemical insights from the spectra may reflect adaptations associated with iron-induced dysregulation. Alterations in biomolecules could reflect systemic stress responses and may result from free radicals generated by the iron-induced Fenton reaction. Moreover, key spectral regions revealed functional interrelationships, particularly between spleen and liver, and heart and kidneys. In summary, the findings support the potential of this innovative for future research to identify IO and quantify iron levels in human blood and different human tissues using only a single drop of blood without tissue biopsies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

IronIron OverloadLiverSpleenHumansKidneyMyocardiumSpectroscopy, Fourier Transform InfraredMaleAnimals

Substanzen

Iron

Autor:innen und Institutionen

  • Departamento of Chemistry, Federal University of Espírito Santo (UFES), Av. Fernando Ferrari, 514, Vitória, Espírito Santo 29075-910, Brazil.
  • Department of Physiological Sciences, Federal University of Espírito Santo (UFES), Av. Marechal Campos, 1468, Maruípe, Vitória, Espírito Santo 29040-090, Brazil.
  • Federal Institute of Education, Science, and Technology of Espírito Santo, Av. Ministro Salgado Filho, 1000, Vila Velha, Espírito Santo 29106-010, Brazil.
  • Department of Cellular Pathology, Blackpool Teaching Hospitals NHS Foundation Trust, Whinney Heys Road, Blackpool FY3 8NR, U.K.

ORCID-Profile: Gabriely S Folli, Anne Louise S Torres, Matthews Martins, Wanderson Romão, Francis L Martin, Paulo R Filgueiras

Förderung

  • Funda??o de Amparo ? Pesquisa e Inova??o do Esp?rito Santo
  • Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico
  • Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior

Zitieren

APA

Folli, G. S., Torres, A. L. S., Martins, M., Silva, L. R. R., Marques, V. B., Carneiro, M. T., Roriz, L. D., Dos Santos, L., Romão, W., Martin, F. L., Filgueiras, P. R., & Barauna, V. G. (2025). One-Drop Serum Screening Test to Monitor Tissue Iron Accumulation. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c00778

Vancouver

Folli GS, Torres ALS, Martins M, Silva LRR, Marques VB, Carneiro MT, et al. One-Drop Serum Screening Test to Monitor Tissue Iron Accumulation. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.5c00778

BibTeX
@article{Folli2025,
  author = {Folli, Gabriely S and Torres, Anne Louise S and Martins, Matthews and Silva, Luiz Ricardo Rodrigues and Marques, Vinícius Bermond and Carneiro, Maria Tereza and Roriz, Larissa Dias and Dos Santos, Leonardo and Romão, Wanderson and Martin, Francis L and Filgueiras, Paulo R and Barauna, Valério G},
  title = {One-Drop Serum Screening Test to Monitor Tissue Iron Accumulation},
  journal = {Analytical Chemistry},
  year = {2025},
  doi = {10.1021/acs.analchem.5c00778}
}
Kostenlos starten →