EUVIMEDEUVIMED entdecken
Open Access

High-Throughput Monoclonal Antibody Peptide Mapping Using 15-s HPLC Gradients Coupled with Cyclic Ion Mobility-Mass Spectrometry

Devin M Makey iD, Brandon T Ruotolo iD, Robert T Kennedy iD

Analytical Chemistry · 12.08.2025 · 97 (31) · 16742-16750

DOI: 10.1021/acs.analchem.5c00741 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 01.08.2025. Verfasst von Devin M Makey und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States. Hauptthemen laut MEDLINE: Antibodies, Monoclonal, Peptide Mapping, Ion Mobility Spectrometry, High-Throughput Screening Assays. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 78 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIGMS NIH HHS, Division of Graduate Education, National Institute of General Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Identification and quantification of critical quality attributes (CQAs) such as sequence variants and post-translational modifications (PTMs) at the residue level are essential for ensuring the safety and efficacy of monoclonal antibody (mAb) therapeutics. Peptide mapping using liquid chromatography coupled to mass spectrometry (LC-MS) allows for the simultaneous monitoring of multiple CQAs, but conventional methods often suffer from low throughput, limiting their utility in applications requiring fast analysis. Here, we present a multidimensional high-throughput peptide mapping workflow that combines fast LC with cyclic ion mobility-mass spectrometry (LC-cIM-MS) for the high-resolution analysis of mAb tryptic digests. A 15-s LC gradient coupled to single-pass cIM-MS achieved a peak capacity of 490 and allowed for a 96-well plate to be analyzed in 37 min, including time for column re-equilibration and autosampler needle washing between each injection. The method yielded a 97% sequence coverage. Repeatability assessments demonstrated robust retention time, arrival time, and peak intensity reproducibility, and a linear dynamic range was observed across nearly 2 orders of magnitude. Mobility-aligned collision-induced dissociation was used to unambiguously localize PTM sites. The fast LC-cIM-MS platform provided site-specific tracking of the oxidation, deamidation, and isomerization kinetics during forced degradation studies. The method offers an approach to assessing CQAs in high-throughput analysis applications such as stability studies, formulation screening, and process monitoring and has the potential to accelerate mAb development and manufacturing. These results also demonstrate the potential of fast multidimensional separations for complex sample analysis.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Antibodies, MonoclonalPeptide MappingIon Mobility SpectrometryHigh-Throughput Screening AssaysChromatography, High Pressure LiquidMass Spectrometry

Substanzen

Antibodies, Monoclonal

Autor:innen und Institutionen

  • Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.
  • Department of Pharmacology, University of Michigan, Ann Arbor, Michigan 48109, United States.

ORCID-Profile: Devin M Makey, Brandon T Ruotolo, Robert T Kennedy

Förderung

  • NIGMS NIH HHS
  • Division of Graduate Education
  • National Institute of General Medical Sciences

Zitieren

APA

Makey, D. M., Ruotolo, B. T., & Kennedy, R. T. (2025). High-Throughput Monoclonal Antibody Peptide Mapping Using 15-s HPLC Gradients Coupled with Cyclic Ion Mobility-Mass Spectrometry. Analytical Chemistry, 97(31), 16742-16750. https://doi.org/10.1021/acs.analchem.5c00741

Vancouver

Makey DM, Ruotolo BT, Kennedy RT. High-Throughput Monoclonal Antibody Peptide Mapping Using 15-s HPLC Gradients Coupled with Cyclic Ion Mobility-Mass Spectrometry. Analytical Chemistry. 2025;97(31):16742-16750. doi:10.1021/acs.analchem.5c00741

BibTeX
@article{Makey2025,
  author = {Makey, Devin M and Ruotolo, Brandon T and Kennedy, Robert T},
  title = {High-Throughput Monoclonal Antibody Peptide Mapping Using 15-s HPLC Gradients Coupled with Cyclic Ion Mobility-Mass Spectrometry},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {31},
  pages = {16742--16750},
  doi = {10.1021/acs.analchem.5c00741}
}
Kostenlos starten →