Ultrasensitive Homogeneous Electrochemiluminescence Biosensor for N -Nitrosodimethylamine Detection Based on Vertically-Ordered Mesoporous Silica Film-Modified Electrode and CRISPR/Cas12a-Driven HRCA with Triple Signal Amplification
Analytical Chemistry · 18.03.2025 · 97 (10) · 5828-5835
DOI: 10.1021/acs.analchem.5c00555 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 04.03.2025. Verfasst von Zhenjie Zheng und 8 weiteren Autor:innen. Beteiligte Einrichtung: College of Biological Science and Engineering, Fuzhou University, Fuzhou, Fujian 350116, China. Hauptthemen laut MEDLINE: Biosensing Techniques, Silicon Dioxide, CRISPR-Cas Systems, Electrochemical Techniques. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Natural Science Foundation of Fujian Province, National Natural Science Foundation of China, Fujian Provincial Department of Ocean Fisheries.
Abstract (Originalsprache)
Herein, we present an innovative electrochemiluminescence (ECL) biosensor for the ultrasensitive detection of N-nitrosodimethylamine (NDMA). The biosensor utilizes a triple signal amplification strategy, combining rolling circle amplification (RCA), CRISPR/Cas12a-driven hyperbranched rolling circle amplification (HRCA), and electrostatic repulsion with size exclusion effects from vertically ordered mesoporous silica film (VMSF)/indium tin oxide (ITO) on double-stranded DNA (dsDNA)-Ru(phen)32+ complexes. In this system, aptamers and circular DNA undergo RCA reactions, followed by the CRISPR/Cas12a-mediated HRCA process, producing abundant dsDNA. The electropositive ECL indicator, namely Ru(phen)32+, was subsequently adsorbed onto the electronegative dsDNA, forming dsDNA-Ru(phen)32+ complexes. These complexes are subjected to electrostatic repulsion and size exclusion by the VMSF-modified ITO electrode, resulting in a lower ECL intensity. Upon introducing NDMA, the aptamer preferentially binds to NDMA, thereby preventing the formation of long dsDNA. This process releases free Ru(phen)32+, which diffuses to the electrode surface through narrow mesoporous channels via electrostatic adsorption. Consequently, an enhanced and strong ECL signal is observed. The integration of VMSF enhances selectivity and sensitivity by excluding larger impurities and promoting the electrostatic repulsion of dsDNA-Ru(phen)32+ complexes near the electrode surface. Additionally, the CRISPR/Cas12a system eliminates the formation of primer dimers and reduces false positives through its unique cis- and trans-cleavage activities. The biosensor demonstrated excellent performance with a linear correlation between the ECL signal and NDMA concentration in the range spanning from 10 pg/mL to 10 μg/mL, achieving a low limit of detection of 5.33 pg/mL. This platform offers a reliable and robust solution for detecting NDMA in complex matrices, making it a promising tool for environmental monitoring, public health, and safety applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- College of Biological Science and Engineering, Fuzhou University, Fuzhou, Fujian 350116, China.
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, 2 Xue Yuan Roa…
- Fisheries Research Institute of Fujian/Key Laboratory of Cultivation and High-value Utilization of Marine Organisms in Fujian Province, Xiamen, Fujian 361013, China.
ORCID-Profile: Da Huang, Zuquan Weng, Jian Wang, Bin Qiu, Zhenyu Lin, Fang Luo
Förderung
- Natural Science Foundation of Fujian Province
- National Natural Science Foundation of China
- Fujian Provincial Department of Ocean Fisheries
- Foundation for Qishan Scholars of Fuzhou University
Zitieren
APA
Zheng, Z., Qian, Z., Huang, D., Weng, Z., Wang, J., Lin, C., Qiu, B., Lin, Z., & Luo, F. (2025). Ultrasensitive Homogeneous Electrochemiluminescence Biosensor for N -Nitrosodimethylamine Detection Based on Vertically-Ordered Mesoporous Silica Film-Modified Electrode and CRISPR/Cas12a-Driven HRCA with Triple Signal Amplification. Analytical Chemistry, 97(10), 5828-5835. https://doi.org/10.1021/acs.analchem.5c00555
Vancouver
Zheng Z, Qian Z, Huang D, Weng Z, Wang J, Lin C, et al. Ultrasensitive Homogeneous Electrochemiluminescence Biosensor for N -Nitrosodimethylamine Detection Based on Vertically-Ordered Mesoporous Silica Film-Modified Electrode and CRISPR/Cas12a-Driven HRCA with Triple Signal Amplification. Analytical Chemistry. 2025;97(10):5828-5835. doi:10.1021/acs.analchem.5c00555
BibTeX
@article{Zheng2025,
author = {Zheng, Zhenjie and Qian, Zhuozhen and Huang, Da and Weng, Zuquan and Wang, Jian and Lin, Cuiying and Qiu, Bin and Lin, Zhenyu and Luo, Fang},
title = {Ultrasensitive Homogeneous Electrochemiluminescence Biosensor for N -Nitrosodimethylamine Detection Based on Vertically-Ordered Mesoporous Silica Film-Modified Electrode and CRISPR/Cas12a-Driven HRCA with Triple Signal Amplification},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {10},
pages = {5828--5835},
doi = {10.1021/acs.analchem.5c00555}
}
EUVIMED