Miniature Thermoelectric Cooler for Long-Term Stable Dehydration for On-Site Breath Analysis by Direct Inlet Photoionization Ion Mobility Spectrometry and Mass Spectrometry

Zhihao Zhang, Huaiwen Cang, Qingyun Li, Yi Yu iD, Huimin Jiao, Yuanyuan Xie, Shan Deng, Jichun Jiang, Lei Hua iD, Haiyang Li iD, Hang Li iD

Analytical Chemistry · 2025

DOI: 10.1021/acs.analchem.5c00138 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Zhihao Zhang und 10 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Medical Proteomics, Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian Institute of Chemica…. Hauptthemen laut MEDLINE: Ion Mobility Spectrometry, Mass Spectrometry, Acetone. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: Dalian Medical University, National Key Research and Development Program of China, Natural Science Foundation of Liaoning Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid and highly frequent measurements of exhaled breath hold significant value for disease diagnosis and exposure assessments. Direct inlet mass spectrometry and ion mobility spectrometry demonstrate great potential for on-site breath analysis, but their accuracy and sensitivity are notably affected by the high humidity in the breath samples. A miniature and continuous dehydration device based on dual-switching thermoelectric cold traps has been developed to efficiently reduce the humidity of breath gas from saturation to relative humidity of 4.3%, and a subcooling compensation method was adopted to eliminate the humidity fluctuations when switching the two cold traps to remove the condensed water in the trap, which could achieve a stable outlet humidity with RSD of 8.2% regardless of inlet humidity variations. The performance and profits of the miniature dehydration device for on-site analysis of breath samples have been tested by coupling with direct inlet photoionization ion mobility spectrometry and time-of-flight mass spectrometry. Trace breath acetone could be directly measured, and its concentration profiles over an 8 h period in fasting volunteers could be continuously monitored every 30 s. Furthermore, the m/z peaks from chlorinated hydrocarbons in exhaled breath samples were clearly identified after passing the dehydration device, which can be used for an occupational health assessment of the widely used halocarbon solvents.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ion Mobility SpectrometryMass SpectrometryAcetoneBreath TestsHumansHumidity

Substanzen

Acetone

Autor:innen und Institutionen

  • State Key Laboratory of Medical Proteomics, Liaoning Key Laboratory for Mass Spectrometry Technology and Instrumentation, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People's Republ…
  • University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China.
  • Second Affiliated Hospital of Dalian Medical University, Dalian 116023, People's Republic of China.
  • State Key Laboratory of Organometallic Chemistry, Shanghai Institute of Organic Chemistry, Chinese Academy of Sciences, Shanghai 200032, People's Republic of China.

ORCID-Profile: Yi Yu, Lei Hua, Haiyang Li, Hang Li

Förderung

  • Dalian Medical University
  • National Key Research and Development Program of China
  • Natural Science Foundation of Liaoning Province
  • National Natural Science Foundation of China
  • Chinese Academy of Sciences
  • United Foundation for Dalian Institute of Chemical Physics
  • Dalian High-Level Talent Innovation Support Project

Zitieren

APA

Zhang, Z., Cang, H., Li, Q., Yu, Y., Jiao, H., Xie, Y., Deng, S., Jiang, J., Hua, L., Li, H., & Li, H. (2025). Miniature Thermoelectric Cooler for Long-Term Stable Dehydration for On-Site Breath Analysis by Direct Inlet Photoionization Ion Mobility Spectrometry and Mass Spectrometry. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c00138

Vancouver

Zhang Z, Cang H, Li Q, Yu Y, Jiao H, Xie Y, et al. Miniature Thermoelectric Cooler for Long-Term Stable Dehydration for On-Site Breath Analysis by Direct Inlet Photoionization Ion Mobility Spectrometry and Mass Spectrometry. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.5c00138

BibTeX
@article{Zhang2025,
  author = {Zhang, Zhihao and Cang, Huaiwen and Li, Qingyun and Yu, Yi and Jiao, Huimin and Xie, Yuanyuan and Deng, Shan and Jiang, Jichun and Hua, Lei and Li, Haiyang and Li, Hang},
  title = {Miniature Thermoelectric Cooler for Long-Term Stable Dehydration for On-Site Breath Analysis by Direct Inlet Photoionization Ion Mobility Spectrometry and Mass Spectrometry},
  journal = {Analytical Chemistry},
  year = {2025},
  doi = {10.1021/acs.analchem.5c00138}
}
Kostenlos starten →