EUVIMEDEUVIMED entdecken
Crossref

Inertial Microfluidics Enables Functional Analysis of Neutrophils Isolated from Ultralow Blood Volume Samples

Roberto Rodriguez-Moncayo iD, Stephanie Pons, Luciana P Tavares, Hyungkook Jeon iD, John-Alexander Preuss, Janina Bahnemann iD, Jongyoon Han, Bruce D Levy, Joel Voldman

Analytical Chemistry · 2025

DOI: 10.1021/acs.analchem.5c00102 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Roberto Rodriguez-Moncayo und 8 weiteren Autor:innen. Beteiligte Einrichtung: Research Laboratory of Electronics, Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology (MIT), Cambridge…. Hauptthemen laut MEDLINE: Neutrophils, Cell Separation, Microfluidic Analytical Techniques, Blood Volume. Die Arbeit nennt 31 Literaturangaben. Gefördert von: National Research Foundation of Korea, Joachim Herz Stiftung, National Institute of General Medical Sciences.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Monitoring immune cell function is increasingly being recognized as a more relevant biomarker than traditional white blood cell counts, yet the need for repeated relatively large blood volumes still continues to pose a significant challenge. To overcome this, we developed a sample-sparing platform using inertial microfluidics that can process as little as 10 μL of blood to isolate leukocytes for downstream functional analysis. Our platform isolates leukocytes with ∼80% purity, >90% in-device recovery, and >95% viability. Neutrophils were our primary focus due to their sensitivity to external stimuli and their critical role in immune responses. Neutrophils isolated through our new method did not show inadvertent activation, as evidenced by unchanged expression of activation markers CD62L and CD11b, with phenotypes comparable to control cells in whole blood. We conducted a range of functional assays, including phagocytosis, ROS production, and NETosis with all tests confirming that neutrophils maintained their functionality after isolation. These assays were performed using standard laboratory workflows, demonstrating the platform's compatibility with techniques such as flow cytometry and cell culture assays. Furthermore, we showed the versatility of our platform by successfully isolating leukocytes from challenging samples, including mouse blood from the vena cava or tail vein, as well as human capillary blood obtained by fingerstick. This adaptability highlights the potential of this platform for clinical and research applications, particularly in frequent immune monitoring or cases where sample volume is limited.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NeutrophilsCell SeparationMicrofluidic Analytical TechniquesBlood VolumeAnimalsHumansMiceReactive Oxygen SpeciesPhagocytosis

Substanzen

Reactive Oxygen Species

Autor:innen und Institutionen

  • Research Laboratory of Electronics, Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology (MIT), Cambridge, Massachusetts 02139, United States.
  • Pulmonary and Critical Care Medicine Division, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts 02115, United States.
  • Department of Manufacturing Systems and Design Engineering (MSDE), Seoul National University of Science and Technology (SEOULTECH), 232 Gongneung-ro, Nowon-gu, Seoul 01811, Republic of Korea.
  • Institute of Physics, University of Augsburg, Augsburg 86159, Germany.
  • Institute of Physics & Center for Advanced Analytics and Predictive Sciences, University of Augsburg, Augsburg 86159, Germany.
  • Research Laboratory of Electronics, Department of Electrical Engineering and Computer Science & Department of Biological Engineering, Massachusetts Institute of Technology (MIT), Cambridge, Massachusetts 02139, United S…

ORCID-Profile: Roberto Rodriguez-Moncayo, Hyungkook Jeon, Janina Bahnemann

Förderung

  • National Research Foundation of Korea
  • Joachim Herz Stiftung
  • National Institute of General Medical Sciences

Zitieren

APA

Rodriguez-Moncayo, R., Pons, S., Tavares, L. P., Jeon, H., Preuss, J. A., Bahnemann, J., Han, J., Levy, B. D., & Voldman, J. (2025). Inertial Microfluidics Enables Functional Analysis of Neutrophils Isolated from Ultralow Blood Volume Samples. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.5c00102

Vancouver

Rodriguez-Moncayo R, Pons S, Tavares LP, Jeon H, Preuss JA, Bahnemann J, et al. Inertial Microfluidics Enables Functional Analysis of Neutrophils Isolated from Ultralow Blood Volume Samples. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.5c00102

BibTeX
@article{RodriguezMoncayo2025,
  author = {Rodriguez-Moncayo, Roberto and Pons, Stephanie and Tavares, Luciana P and Jeon, Hyungkook and Preuss, John-Alexander and Bahnemann, Janina and Han, Jongyoon and Levy, Bruce D and Voldman, Joel},
  title = {Inertial Microfluidics Enables Functional Analysis of Neutrophils Isolated from Ultralow Blood Volume Samples},
  journal = {Analytical Chemistry},
  year = {2025},
  doi = {10.1021/acs.analchem.5c00102}
}
Kostenlos starten →