EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Electrogenerated Chemiluminescence Coupled with Molecularly Imprinted Polymer for Sensitive and Selective Detection of N , N -Dimethyltryptamine

Jesy Alka Motchaalangaram, Paramasivam Mahalingam iD, Karl J Wallace iD, Wujian Miao iD

Analytical Chemistry · 25.03.2025 · 97 (11) · 6163-6174

DOI: 10.1021/acs.analchem.4c06886 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 14.03.2025. Verfasst von Jesy Alka Motchaalangaram und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry and Biochemistry, The University of Southern Mississippi, Hattiesburg, Mississippi 39406, United States. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: U.S. Department of Defense.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A simple and efficient approach that combined electrogenerated chemiluminescence (ECL) and molecularly imprinted polymers (MIPs) for selective and sensitive detection of the hallucinogenic drug N,N-dimethyltryptamine (DMT) was developed. ECL, one of the most sensitive analytical techniques for ultratrace analyte detection, offers the advantage of light-free spectroscopic analysis initiated by electrochemistry. MIPs, on the other hand, provide specific binding sites, allowing the target analyte to become selectively imprinted within the polymer matrix. In this study, an ECL coupled-MIP sensor was fabricated using para-aminobenzoic acid (p-ABA) as the monomer and DMT as the template molecule. The MIP was electropolymerized onto a glassy carbon electrode coated with a Nafion film entrapping [Ru(bpy)3]2+ species. Following elution, the imprinted sites were reoccupied by DMT, generating ECL signals in a phosphate buffered solution during anodic potential scanning. The ECL-MIP sensor demonstrated a wide dynamic range for DMT detection, from 0.5 to 300 μM, with an estimated detection limit of 0.5-1.0 μM (S/N = 3). The sensor's reproducibility, stability, and selectivity were also evaluated. Finally, density functional theory was employed to investigate the structure-property relationship of the p-ABA-DMT interaction. This work demonstrated the potential of ECL coupled with MIP technology for identifying structurally related molecules, achieving enhanced selectivity with a simple and cost-effective design.

Autor:innen und Institutionen

  • Department of Chemistry and Biochemistry, The University of Southern Mississippi, Hattiesburg, Mississippi 39406, United States.
  • School of Polymer Science and Engineering, The University of Southern Mississippi, Hattiesburg, Mississippi 39406, United States.

ORCID-Profile: Paramasivam Mahalingam, Karl J Wallace, Wujian Miao

Förderung

  • U.S. Department of Defense

Zitieren

APA

Motchaalangaram, J. A., Mahalingam, P., Wallace, K. J., & Miao, W. (2025). Electrogenerated Chemiluminescence Coupled with Molecularly Imprinted Polymer for Sensitive and Selective Detection of N , N -Dimethyltryptamine. Analytical Chemistry, 97(11), 6163-6174. https://doi.org/10.1021/acs.analchem.4c06886

Vancouver

Motchaalangaram JA, Mahalingam P, Wallace KJ, Miao W. Electrogenerated Chemiluminescence Coupled with Molecularly Imprinted Polymer for Sensitive and Selective Detection of N , N -Dimethyltryptamine. Analytical Chemistry. 2025;97(11):6163-6174. doi:10.1021/acs.analchem.4c06886

BibTeX
@article{Motchaalangaram2025,
  author = {Motchaalangaram, Jesy Alka and Mahalingam, Paramasivam and Wallace, Karl J and Miao, Wujian},
  title = {Electrogenerated Chemiluminescence Coupled with Molecularly Imprinted Polymer for Sensitive and Selective Detection of N , N -Dimethyltryptamine},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {11},
  pages = {6163--6174},
  doi = {10.1021/acs.analchem.4c06886}
}
Kostenlos starten →