Addressing Buffer, Size, and Clogging Challenges in LAMP-Coupled Solid-State Nanopores for Point-of-Care Testing

Ming Dong iD, Aneesh Kshirsagar iD, Anthony J Politza iD, Muhammad Asad Ullah Khalid iD, Md Ahasan Ahamed, Weihua Guan iD

Analytical Chemistry · 2025

DOI: 10.1021/acs.analchem.4c06823 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Ming Dong und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States. Hauptthemen laut MEDLINE: Nanopores, Nucleic Acid Amplification Techniques, Point-of-Care Testing, Molecular Diagnostic Techniques. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Institute of Allergy and Infectious Diseases, National Science Foundation, U.S. Department of Agriculture.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Loop-mediated isothermal amplification (LAMP) is a promising method for point-of-care nucleic acid testing due to its simplicity, rapidity, and high sensitivity. Coupling LAMP with solid-state nanopores enables label-free, single-molecule sensing, enhancing diagnostic accuracy. However, conventional LAMP-coupled nanopore protocols require high-salt buffers (>1 M) to improve signal strength and translocation frequency, complicating workflows and increasing contamination risks. In native LAMP buffers (50 mM KCl), electroosmotic flow (EOF) hinders amplicon transport in sub-10 nm pores, while large amplicons increase the risk of clogging. These challenges limit event rates, data throughput, and device reliability. To address these limitations, we developed a glass nanopore device optimized for direct sensing of amplicons in native buffers, featuring integrated declogging capabilities. Our results revealed that 200 nm pores provided the best balance between minimizing EOF interference and maintaining strong signal strength, achieving the highest event rates. Smaller pores ( 1 μm) showed weakened signal strength. We discovered that clogging in low-salt conditions differs from high-salt environments, with physical vibration effectively resolving clogging in low-salt settings. This led to the integration of an automated vibration motor, extending nanopore lifespan and ensuring continuous data acquisition. Our clog-free, native-buffer sensing platform demonstrated a sensitivity of 0.12 parasite/μL using Plasmodium vivax (P. vivax) as a model organism, exceeding the threshold for detecting asymptomatic infections. These advancements highlight the potential of our nanopore device for rapid, reliable, and user-friendly diagnostics for point-of-care testing.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NanoporesNucleic Acid Amplification TechniquesPoint-of-Care TestingMolecular Diagnostic TechniquesBuffersHumansParticle SizeElectroosmosis

Substanzen

Buffers

Autor:innen und Institutionen

  • Department of Electrical Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States.
  • Department of Biomedical Engineering, Pennsylvania State University, University Park, Pennsylvania 16802, United States.
  • Department of Intelligent Systems Engineering, Luddy School of Informatics, Computing, and Engineering, Indiana University, Bloomington, Indiana 47408, United States.

ORCID-Profile: Ming Dong, Aneesh Kshirsagar, Anthony J Politza, Muhammad Asad Ullah Khalid, Weihua Guan

Förderung

  • National Institute of Allergy and Infectious Diseases
  • National Science Foundation
  • U.S. Department of Agriculture

Zitieren

APA

Dong, M., Kshirsagar, A., Politza, A. J., Khalid, M. A. U., Ahamed, M. A., & Guan, W. (2025). Addressing Buffer, Size, and Clogging Challenges in LAMP-Coupled Solid-State Nanopores for Point-of-Care Testing. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c06823

Vancouver

Dong M, Kshirsagar A, Politza AJ, Khalid MAU, Ahamed MA, Guan W. Addressing Buffer, Size, and Clogging Challenges in LAMP-Coupled Solid-State Nanopores for Point-of-Care Testing. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.4c06823

BibTeX
@article{Dong2025,
  author = {Dong, Ming and Kshirsagar, Aneesh and Politza, Anthony J and Khalid, Muhammad Asad Ullah and Ahamed, Md Ahasan and Guan, Weihua},
  title = {Addressing Buffer, Size, and Clogging Challenges in LAMP-Coupled Solid-State Nanopores for Point-of-Care Testing},
  journal = {Analytical Chemistry},
  year = {2025},
  doi = {10.1021/acs.analchem.4c06823}
}
Kostenlos starten →