Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 10.03.2025. Verfasst von Motoki Inoue und 2 weiteren Autor:innen. Beteiligte Einrichtung: Hoshi University, 2-4-41, Ebara, Shinagawa-ku, Tokyo 142-8501, Japan. Hauptthemen laut MEDLINE: Tablets. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 22 Literaturangaben. Gefördert von: Japan Society for the Promotion of Science.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Real-time monitoring of solid dosage forms is crucial in continuous manufacturing processes for detecting product variability and bias and minimizing defective products. Traditional process analytical technologies often struggle to maintain high-throughput production. This study presents a novel approach using near-infrared (NIR) transmission spectroscopy for rapidly and comprehensively assessing the quality of solid dosage forms. A chemometric model was developed, based on NIR spectra obtained from tablets produced through wet granulation, to accurately predict active pharmaceutical ingredient (API). Performance was validated against the conventional high-performance liquid chromatography (HPLC) method, achieving a high correlation coefficient (R2 = 0.9979) and a low root-mean-square error of prediction (RMSEP = 1.09%). Critically, even at a high inspection speed of 250,000 tablets/h, the method maintained high analytical accuracy (RMSEP = 1.19%) and met content uniformity requirements (±15%). With negligible bias compared with HPLC across all formulations, the proposed NIR transmission spectroscopy method offers a powerful alternative for the rapid and precise quantification of API content and real-time quality control, thereby substantially contributing to quality assurance in continuous manufacturing processes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TabletsSpectroscopy, Near-InfraredChromatography, High Pressure Liquid

Substanzen

Tablets

Autor:innen und Institutionen

  • Hoshi University, 2-4-41, Ebara, Shinagawa-ku, Tokyo 142-8501, Japan.
  • Anritsu Corporation, 5-1-1, Onna, Atsugi-shi, Kanagawa 243-8555, Japan.

ORCID-Profile: Motoki Inoue

Förderung

  • Japan Society for the Promotion of Science

Zitieren

APA

Inoue, M., Taniguchi, E., & Sano, J. (2025). Real-Time Total Content Uniformity Assessment of Solid Dosage Forms Using Near-Infrared Transmission Spectroscopy. Analytical Chemistry, 97(11), 6111-6117. https://doi.org/10.1021/acs.analchem.4c06733

Vancouver

Inoue M, Taniguchi E, Sano J. Real-Time Total Content Uniformity Assessment of Solid Dosage Forms Using Near-Infrared Transmission Spectroscopy. Analytical Chemistry. 2025;97(11):6111-6117. doi:10.1021/acs.analchem.4c06733

BibTeX
@article{Inoue2025,
  author = {Inoue, Motoki and Taniguchi, Eiji and Sano, Junichi},
  title = {Real-Time Total Content Uniformity Assessment of Solid Dosage Forms Using Near-Infrared Transmission Spectroscopy},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {11},
  pages = {6111--6117},
  doi = {10.1021/acs.analchem.4c06733}
}
Kostenlos starten →