Construction of a Self-Enhanced Electrochemiluminescent Sensor Based on Tandem Signal Amplification and a Self-Luminescent Lanthanide Covalent-Organic Polymer for Ochratoxin A Assay
Analytical Chemistry · 25.02.2025 · 97 (7) · 4217-4223
DOI: 10.1021/acs.analchem.4c06658 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, erschienen am 25.02.2025. Verfasst von Linlin Song und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, China. Hauptthemen laut MEDLINE: Ochratoxins, Luminescent Measurements, Electrochemical Techniques, Biosensing Techniques. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 45 Literaturangaben. Gefördert von: State Key Laboratory of Analytical Chemistry for Life Sciences, National Natural Science Foundation of China.
Abstract (Originalsprache)
Ochratoxin A (OTA) is a type of mycotoxin found in various contaminated foods, and it is highly toxic to the livers and kidneys of humans. Herein, we develop a self-enhanced electrochemiluminescent (ECL) sensor based on tandem signal amplification and a self-luminescent europium covalent-organic polymer (Eu-COPTMT-BPA) for OTA assay. Eu-COPTMT-BPA is a self-enhanced ECL emitter that is obtained by using 2,4,6-trimethyl-1,3,5-triazine (TMT) and 2,2'-bipyridine-5,5'-dicarbaldehyde (BPA) as the first and second ligands to form a highly conjugated structure for sensitizing the Eu3+ luminescence. In Eu-COPTMT-BPA, BPA can adjust the energy gap between the triplet ligand and Eu3+excited state to achieve rapid and effective energy transfer for the generation of an enhanced ECL signal. When target OTA is present, it binds with the aptamer segment of the hairpin aptamer probe (HAP) to form a tight structure. The exposed sequence of HAP subsequently binds with the hairpin probe 1/single-stranded DNA 1 (HP1/S1) hybrid to release OTA and trigger (S1). The released S1 can be recognized by a magnetic bead (MB)-capture probe conjugate to trigger a hybridization chain reaction (HCR) between Fc-labeled HP2 and Fc-labeled HP3, leading to the formation of long double-stranded DNA (dsDNA) nanowires on the MB surface and the accumulation of abundant Fc that can quench the ECL intensity of the Eu-COPTMT-BPA/TPrA system. This ECL sensor exhibits good stability, excellent specificity, and high sensitivity, with a detection limit (LOD) of 0.47 fg/mL and a linear range of 1 pg/mL-10 ng/mL, and it can quantitatively measure OTA in wine and coffee.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- College of Chemistry, Chemical Engineering and Materials Science, Shandong Normal University, Jinan 250014, China.
- School of Chemistry and Chemical Engineering, State Key Laboratory of Digital Medical Engineering, Southeast University, Nanjing 211189, China.
ORCID-Profile: Lin Cui, Chun-Yang Zhang
Förderung
- State Key Laboratory of Analytical Chemistry for Life Sciences
- National Natural Science Foundation of China
Zitieren
APA
Song, L., Cao, X., Yang, Y., Chu, W., Zou, X., Cui, L., & Zhang, C. Y. (2025). Construction of a Self-Enhanced Electrochemiluminescent Sensor Based on Tandem Signal Amplification and a Self-Luminescent Lanthanide Covalent-Organic Polymer for Ochratoxin A Assay. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c06658
Vancouver
Song L, Cao X, Yang Y, Chu W, Zou X, Cui L, et al. Construction of a Self-Enhanced Electrochemiluminescent Sensor Based on Tandem Signal Amplification and a Self-Luminescent Lanthanide Covalent-Organic Polymer for Ochratoxin A Assay. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.4c06658
BibTeX
@article{Song2025,
author = {Song, Linlin and Cao, Xueting and Yang, Yuncong and Chu, Wenqi and Zou, Xiaoran and Cui, Lin and Zhang, Chun-Yang},
title = {Construction of a Self-Enhanced Electrochemiluminescent Sensor Based on Tandem Signal Amplification and a Self-Luminescent Lanthanide Covalent-Organic Polymer for Ochratoxin A Assay},
journal = {Analytical Chemistry},
year = {2025},
doi = {10.1021/acs.analchem.4c06658}
}