EUVIMEDEUVIMED entdecken
Crossref

TimePAD─Unveiling Temporal Sequence ELISA Signal by Deep Learning for Rapid Readout and Improved Accuracy in a Microfluidic Paper-Based Analytical Platform

Jia Zhu, Kai Hoettges, Yongjie Wang iD, Haibo Ma, Pengfei Song iD, Yong Hu, Eng Gee Lim, Quan Zhang

Analytical Chemistry · 04.03.2025 · 97 (8) · 4515-4523

DOI: 10.1021/acs.analchem.4c06001 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 17.02.2025. Verfasst von Jia Zhu und 7 weiteren Autor:innen. Beteiligte Einrichtung: School of Advanced Technology, Xi'an Jiaotong-Liverpool University, Suzhou, Jiangsu 215000, China. Hauptthemen laut MEDLINE: Paper, Deep Learning, Immunoglobulin G, Microfluidic Analytical Techniques. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Major Basic Research Project of the Natural Science Foundation of the Jiangsu Higher Education Institutions, State Key Laboratory for Manufacturing Systems Engineering, Jiangsu Province Engineering Research Centre of Data Science and Cognitive Computation at XJTLU.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The integration of paper-based microfluidics with deep learning represents a pivotal trend in enhancing diagnostic capabilities. This paper introduces a new approach to improve the performance of a paper-based microfluidic enzyme-linked immunosorbent assay (ELISA) by training the temporal sequence colorimetric data rather than static data conventionally, using deep learning. Traditional deep learning-assisted ELISA analysis methods usually rely on a single snapshot of the reaction at its end, which limits the further improvement of sensitivity and specificity (or accuracy for combined evaluation), as it misses dynamic changes in the reaction over time. In this work, we developed a temporal sequence-enhanced paper analytical device (TimePAD) that captures continuous video data of the ELISA reaction, which contains the dynamic colorimetric changes. With the YOLOv8 deep learning alogrithm and the Rabbit IgG as the model for ELISA assay, we can use the initial 20 min signal instead of waiting for 30 min for full reaction, achieving a 33% reduction in the turnaround time. Moreover, the overall accuracy at 20 min is 94.1%, which is slightly improvement to the 93.5% using a traditional single snapshot method at 30 min. This method not only accelerates result interpretation but also enhances the overall efficiency of diagnostics, making it particularly valuable for time-sensitive point-of-care testing applications. Lastly, to demonstrate its real-world use, we expanded to the disease biomarker cTnI detection and obtained accuracy of 98.1% within only 10 min, compared to 25 min with 97.8% accuracy in traditional methods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PaperDeep LearningImmunoglobulin GMicrofluidic Analytical TechniquesLab-On-A-Chip DevicesEnzyme-Linked Immunosorbent AssayAnimalsRabbitsColorimetryTime Factors

Substanzen

Immunoglobulin G

Autor:innen und Institutionen

  • School of Advanced Technology, Xi'an Jiaotong-Liverpool University, Suzhou, Jiangsu 215000, China.
  • School of Intelligent Manufacturing and Smart Transportation, Suzhou City University, Suzhou, Jiangsu 215000, China.
  • Department of Electrical and Electronic Engineering, University of Liverpool, Liverpool L69 3GJ, U.K.
  • School of Science, Harbin Institute of Technology-Shenzhen 518000 Shenzhen, China.
  • School of Mechanical and Aerospace Engineering, Jilin University, Changchun, Jilin 130000, China.

ORCID-Profile: Yongjie Wang, Pengfei Song

Förderung

  • Major Basic Research Project of the Natural Science Foundation of the Jiangsu Higher Education Institutions
  • State Key Laboratory for Manufacturing Systems Engineering
  • Jiangsu Province Engineering Research Centre of Data Science and Cognitive Computation at XJTLU
  • XJTLU AI University Research Centre
  • XJTLU University RDF project
  • Key Laboratory of Bionic Engineering, Ministry of Education
  • SIP AI innovation platform

Zitieren

APA

Zhu, J., Hoettges, K., Wang, Y., Ma, H., Song, P., Hu, Y., Lim, E. G., & Zhang, Q. (2025). TimePAD─Unveiling Temporal Sequence ELISA Signal by Deep Learning for Rapid Readout and Improved Accuracy in a Microfluidic Paper-Based Analytical Platform. Analytical Chemistry, 97(8), 4515-4523. https://doi.org/10.1021/acs.analchem.4c06001

Vancouver

Zhu J, Hoettges K, Wang Y, Ma H, Song P, Hu Y, et al. TimePAD─Unveiling Temporal Sequence ELISA Signal by Deep Learning for Rapid Readout and Improved Accuracy in a Microfluidic Paper-Based Analytical Platform. Analytical Chemistry. 2025;97(8):4515-4523. doi:10.1021/acs.analchem.4c06001

BibTeX
@article{Zhu2025,
  author = {Zhu, Jia and Hoettges, Kai and Wang, Yongjie and Ma, Haibo and Song, Pengfei and Hu, Yong and Lim, Eng Gee and Zhang, Quan},
  title = {TimePAD─Unveiling Temporal Sequence ELISA Signal by Deep Learning for Rapid Readout and Improved Accuracy in a Microfluidic Paper-Based Analytical Platform},
  journal = {Analytical Chemistry},
  year = {2025},
  volume = {97},
  number = {8},
  pages = {4515--4523},
  doi = {10.1021/acs.analchem.4c06001}
}