Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2025. Verfasst von Xi Gao und 6 weiteren Autor:innen. Beteiligte Einrichtung: Center for Advanced Materials Research & Faculty of Arts and Sciences, Beijing Normal University, Zhuhai 519087, P. R. China. Hauptthemen laut MEDLINE: Fluorescent Dyes, Xanthenes, Optical Imaging, Drug Design. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: Beijing Normal University, Natural Science Foundation of Beijing Municipality, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The development of long-wavelength near-infrared II (NIR-II, 900–1700 nm) dyes is highly desirable but challenging. To achieve both red-shifted absorption/emission and superior in vivo imaging capabilities, a donor–acceptor–donor (D–A–D) xanthene core was strategically modified by extending π-conjugated double bonds and enhancing electron-donating properties. Two dyes named VIX-1250 and VIX-1450 were synthesized and exhibited notably red-shifted absorption/emission peaks at 942/1250 and 1098/1450 nm, respectively. Among them, VIX-1450 demonstrated superior chemo- and photostability even at such long wavelengths. Fluorescent angiography using VIX-1450 micelles enabled high-clarity blood vessel imaging with a remarkable signal-to-noise ratio (SNR), underscoring that the dye’s large Stokes shift (352 nm), good brightness (13 M –1 cm –1 ), and long wavelength served as key factors for high-quality in vivo biosensing. Additionally, VIX-1450 combined with ICG for dual-color imaging achieved near-zero optical cross talk, enabling different organ labeling. This study provides a new direction for the design of long-wavelength organic dyes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Fluorescent DyesXanthenesOptical ImagingDrug DesignAnimalsMiceHumansInfrared RaysMolecular StructureMicelles

Substanzen

Fluorescent DyesXanthenesMicelles

Autor:innen und Institutionen

  • Center for Advanced Materials Research & Faculty of Arts and Sciences, Beijing Normal University, Zhuhai 519087, P. R. China.
  • Key Laboratory of Radiopharmaceuticals, Ministry of Education, College of Chemistry, Beijing Normal University, Beijing 100875, P. R. China.

ORCID-Profile: Ya-Jun Liu, Kaixiang Zhou, Mengchao Cui

Förderung

  • Beijing Normal University
  • Natural Science Foundation of Beijing Municipality
  • National Natural Science Foundation of China
  • Guangdong Provincial Ordinary Universities Youth Innovation Talent Project

Zitieren

APA

Gao, X., Wang, J. Y., Qin, Y., Zhu, Y., Liu, Y. J., Zhou, K., & Cui, M. (2025). Design, Synthesis, and In Vivo Imaging of a Stable Xanthene-Based Dye with NIR-II Emission up to 1450 nm. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c05794

Vancouver

Gao X, Wang JY, Qin Y, Zhu Y, Liu YJ, Zhou K, et al. Design, Synthesis, and In Vivo Imaging of a Stable Xanthene-Based Dye with NIR-II Emission up to 1450 nm. Analytical Chemistry. 2025. doi:10.1021/acs.analchem.4c05794

BibTeX
@article{Gao2025,
  author = {Gao, Xi and Wang, Jin-Yu and Qin, Yufei and Zhu, Yiling and Liu, Ya-Jun and Zhou, Kaixiang and Cui, Mengchao},
  title = {Design, Synthesis, and In Vivo Imaging of a Stable Xanthene-Based Dye with NIR-II Emission up to 1450 nm},
  journal = {Analytical Chemistry},
  year = {2025},
  doi = {10.1021/acs.analchem.4c05794}
}
Kostenlos starten →