High Selectivity Fluorescence and Electrochemical Dual-Mode Detection of Glutathione in the Serum of Parkinson’s Disease Model Mice and Humans
Analytical Chemistry · 21.01.2025 · 97 (2) · 1318-1328
DOI: 10.1021/acs.analchem.4c05627 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 09.01.2025. Verfasst von Hui Dong und 10 weiteren Autor:innen. Beteiligte Einrichtung: Henan Key Laboratory of Biomolecular Recognition and Sensing, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis o…. Hauptthemen laut MEDLINE: Electrochemistry, Glutathione, Parkinson Disease, Fluorescent Dyes. Die Arbeit wurde bisher 70-mal zitiert (Crossref) und nennt 65 Literaturangaben. Gefördert von: Natural Science Foundation of Henan Province, Henan Province Science and Technology Innovation Talent Program, National Natural Science Foundation of China.
Abstract (Originalsprache)
Parkinson's disease (PD) is a progressive neurodegenerative disorder characterized by the loss of dopaminergic neurons and the accumulation of alpha-synuclein. Glutathione (GSH), a key antioxidant, is significantly depleted in PD patients. This study presents a dual-mode detection strategy for selectively determining GSH using a single probe. A series of "turn-on" electrochemical and fluorescent probes were developed, with resorufin (Re) serving as the reporting unit and featuring specific GSH recognition sites. Among these, the 7-(3,5-dinitrophenoxy)-3H-phenoxazin-3-one (Re-DNP) probe was selected for its high selectivity as both a fluorescent and electrochemical probe. Its response to GSH was superior in comparison to that observed for hydrogen sulfide (H2S) and cysteine (Cys). For electrochemical detection using screen-printed carbon electrode (SPCE)/carbon nanotube (CNT) modified electrodes, the detection limit for GSH was 5 μM, with a linear range of 25-500 μM. In fluorescence detection, the probe produced a 78-fold increase in emission at 630 nm in the presence of GSH, with a strong linear correlation between fluorescence intensity and GSH concentration in the range of 10-700 μM, and a detection limit of 2 μM. When applied to real clinical serum samples, the probe demonstrated significantly lower GSH levels in both PD mice and human patients compared to healthy controls. This dual-mode detection method provides a sensitive and accurate tool for GSH detection, with potential applications in understanding GSH's role in PD and related neurodegenerative diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Henan Key Laboratory of Biomolecular Recognition and Sensing, Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases, College of Chemistry and Chemical Engineering, Shang…
- College of Chemistry, Zhengzhou University, Zhengzhou 450001, China.
- School of Chemistry & Materials Engineering, Xinxiang University, Xinxiang 453000, China.
ORCID-Profile: Hui Dong, Maotian Xu
Förderung
- Natural Science Foundation of Henan Province
- Henan Province Science and Technology Innovation Talent Program
- National Natural Science Foundation of China
- Excellent Youth Fund of Henan Province
- Foundation for University Young Key Teacher of Henan Province
- Program for Innovative Research Team in University of Henan Province
- Henan Joint International Research Laboratory of Chemo/Biosensing and Early Diagnosis of Major Diseases
Zitieren
APA
Dong, H., Chen, W., Xu, K., Zheng, L., Wei, B., Liu, R., Yang, J., Wang, T., Zhou, Y., Zhang, Y., & Xu, M. (2025). High Selectivity Fluorescence and Electrochemical Dual-Mode Detection of Glutathione in the Serum of Parkinson’s Disease Model Mice and Humans. Analytical Chemistry, 97(2), 1318-1328. https://doi.org/10.1021/acs.analchem.4c05627
Vancouver
Dong H, Chen W, Xu K, Zheng L, Wei B, Liu R, et al. High Selectivity Fluorescence and Electrochemical Dual-Mode Detection of Glutathione in the Serum of Parkinson’s Disease Model Mice and Humans. Analytical Chemistry. 2025;97(2):1318-1328. doi:10.1021/acs.analchem.4c05627
BibTeX
@article{Dong2025,
author = {Dong, Hui and Chen, Weitian and Xu, Ke and Zheng, Linlin and Wei, Bingyu and Liu, Ruiyu and Yang, Jingru and Wang, Tao and Zhou, Yanli and Zhang, Yintang and Xu, Maotian},
title = {High Selectivity Fluorescence and Electrochemical Dual-Mode Detection of Glutathione in the Serum of Parkinson’s Disease Model Mice and Humans},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {2},
pages = {1318--1328},
doi = {10.1021/acs.analchem.4c05627}
}
EUVIMED