Real-Time Detection of Methylmercury and Hg(II) Using a Reversible Ratiometric Fluorescent Probe in Cellular and Aqueous Environments
Analytical Chemistry · 25.03.2025 · 97 (11) · 5982-5991
DOI: 10.1021/acs.analchem.4c05362 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 13.03.2025. Verfasst von Hyojin Park und 5 weiteren Autor:innen. Beteiligte Einrichtung: Education and Research Center for Smart Energy Materials and Process, Department of Chemistry and Chemical Engineering, Inha University, Incheon 2221…. Hauptthemen laut MEDLINE: Fluorescent Dyes, Methylmercury Compounds, Mercury, Water Pollutants, Chemical. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Inha University.
Abstract (Originalsprache)
Methylmercury (CH3Hg(I)), produced by the action of aquatic bacteria on inorganic mercury, is the most hazardous among the mercury species. To date, no ratiometric fluorescent probes have been reported for the detection of both CH3Hg(I) and Hg(II) in aquatic environments and in live cells. Herein, we designed a novel fluorescent probe incorporating a peptide containing a histidine residue with self-assembly properties specific to both mercury species and a fluorophore that exhibits red-shifted emissions upon aggregation. The probe effectively detected Hg(II) and CH3Hg(I) in aqueous solutions (1% DMSO) through ratiometric fluorescence sensing with visible-light excitation (445 nm). The probe exhibited high selectivity for Hg(II) and CH3Hg(I) among 19 metal ions, rapid response times (
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Education and Research Center for Smart Energy Materials and Process, Department of Chemistry and Chemical Engineering, Inha University, Incheon 22212, South Korea.
- Department in Biomedical Sciences, College of Medicine, Inha University, Incheon 22212, South Korea.
- Program in Biomedical Sciences & Engineering, Inha University, Incheon 22212, South Korea.
ORCID-Profile: Eun-Taex Oh, Keun-Hyeung Lee
Förderung
- Inha University
Zitieren
APA
Park, H., Oh, E. T., Park, J., Subedi, S., Park, H. J., & Lee, K. H. (2025). Real-Time Detection of Methylmercury and Hg(II) Using a Reversible Ratiometric Fluorescent Probe in Cellular and Aqueous Environments. Analytical Chemistry, 97(11), 5982-5991. https://doi.org/10.1021/acs.analchem.4c05362
Vancouver
Park H, Oh ET, Park J, Subedi S, Park HJ, Lee KH. Real-Time Detection of Methylmercury and Hg(II) Using a Reversible Ratiometric Fluorescent Probe in Cellular and Aqueous Environments. Analytical Chemistry. 2025;97(11):5982-5991. doi:10.1021/acs.analchem.4c05362
BibTeX
@article{Park2025,
author = {Park, Hyojin and Oh, Eun-Taex and Park, Jieun and Subedi, Sumita and Park, Heon Joo and Lee, Keun-Hyeung},
title = {Real-Time Detection of Methylmercury and Hg(II) Using a Reversible Ratiometric Fluorescent Probe in Cellular and Aqueous Environments},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {11},
pages = {5982--5991},
doi = {10.1021/acs.analchem.4c05362}
}
EUVIMED