EUVIMEDEUVIMED entdecken
Crossref

Novel Ratiometric Surface-Enhanced Raman Scattering (SERS) Biosensor for Ultrasensitive Quantitative Monitoring of Human Carboxylesterase-1 in Hepatocellular Carcinoma Cells Using Ag–Au Nanoflowers as SERS Substrate

Hao Cheng, Ruijue Chen, Yaqin Zhan, Wuheng Dong, Qiying Chen, Ying Wang, Pei Zhou, Si Gao, Wenyi Huang, Lijun Li, Jun Feng iD

Analytical Chemistry · 19.11.2024 · 96 (46) · 18555-18563

DOI: 10.1021/acs.analchem.4c04763 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 05.11.2024. Verfasst von Hao Cheng und 10 weiteren Autor:innen. Beteiligte Einrichtung: Guangxi Key Laboratory of Green Processing of Sugar Resources, Department of Medicine, College of Biological and Chemical Engineering, Guangxi Univer…. Hauptthemen laut MEDLINE: Spectrum Analysis, Raman, Biosensing Techniques, Silver, Gold. Die Arbeit wurde bisher 83-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: Specific Research Project of Guangxi for Research Bases and Talents, Natural Science Foundation of Guangxi Zhuang Autonomous Region, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this study, we developed ratiometric surface-enhanced Raman scattering (SERS) biosensors using Ag-Au alloy nanoflowers as SERS substrates, molecules having amide bonds and alkyne groups (Tag A) as Raman reporters, and sodium thiocyanate as an internal standard molecule (Tag B) for the sensitive detection of human carboxylesterase-1 (hCE1) in HepG-2 cells. The correlation between HepG-2 cell damage and hCE1 activity levels was investigated. Both Tag A's alkyne group and Tag B's cyanide group produced characteristic SERS signals in the Raman-silent region (I2000 cm-1 and I2115 cm-1, respectively). The hydrolysis of the amide bond in Tag A via hCE1 and the shedding of the alkyne group led to a reduction in the SERS signal intensity observed at I2000 cm-1. Conversely, the SERS signal intensity of Tag B at I2115 cm-1 exhibited a consistent pattern. As the activity level of hCE1 and the ratiometric peak intensity (I2000 cm-1/I2115 cm-1) correlated negatively, hCE1 could be quantitatively detected within the range of 10-2 to 2 × 102 ng·mL-1, with a detection limit of 7.3 pg·mL-1. The ratiometric SERS probe strategy, in which a ratio response is employed, permits sensitive and reproducible SERS detection by facilitating intrinsic calibration to rectify signal fluctuations resulting from temporal and spatial variations in the detection conditions. Concurrently, the implementation of Raman-silent region reporter molecules mitigates the interference from endogenous biomolecules in SERS measurements and offers a novel approach for achieving highly sensitive and interference-free detection of intracellular hCE1.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Spectrum Analysis, RamanBiosensing TechniquesSilverGoldCarboxylic Ester HydrolasesLiver NeoplasmsCarcinoma, HepatocellularHumansHep G2 CellsMetal NanoparticlesSurface PropertiesLimit of Detection

Substanzen

SilverGoldCES1 protein, humanCarboxylic Ester Hydrolases

Autor:innen und Institutionen

  • Guangxi Key Laboratory of Green Processing of Sugar Resources, Department of Medicine, College of Biological and Chemical Engineering, Guangxi University of Science and Technology, Liuzhou 545006, Guangxi, P. R. China.
  • Provine and Ministry Co-Sponsored Collaborative Innovation Center of Sugarcane and Sugar Industry, Nanning 530004, Guangxi, P. R. China.

ORCID-Profile: Jun Feng

Förderung

  • Specific Research Project of Guangxi for Research Bases and Talents
  • Natural Science Foundation of Guangxi Zhuang Autonomous Region
  • National Natural Science Foundation of China

Zitieren

APA

Cheng, H., Chen, R., Zhan, Y., Dong, W., Chen, Q., Wang, Y., Zhou, P., Gao, S., Huang, W., Li, L., & Feng, J. (2024). Novel Ratiometric Surface-Enhanced Raman Scattering (SERS) Biosensor for Ultrasensitive Quantitative Monitoring of Human Carboxylesterase-1 in Hepatocellular Carcinoma Cells Using Ag–Au Nanoflowers as SERS Substrate. Analytical Chemistry, 96(46), 18555-18563. https://doi.org/10.1021/acs.analchem.4c04763

Vancouver

Cheng H, Chen R, Zhan Y, Dong W, Chen Q, Wang Y, et al. Novel Ratiometric Surface-Enhanced Raman Scattering (SERS) Biosensor for Ultrasensitive Quantitative Monitoring of Human Carboxylesterase-1 in Hepatocellular Carcinoma Cells Using Ag–Au Nanoflowers as SERS Substrate. Analytical Chemistry. 2024;96(46):18555-18563. doi:10.1021/acs.analchem.4c04763

BibTeX
@article{Cheng2024,
  author = {Cheng, Hao and Chen, Ruijue and Zhan, Yaqin and Dong, Wuheng and Chen, Qiying and Wang, Ying and Zhou, Pei and Gao, Si and Huang, Wenyi and Li, Lijun and Feng, Jun},
  title = {Novel Ratiometric Surface-Enhanced Raman Scattering (SERS) Biosensor for Ultrasensitive Quantitative Monitoring of Human Carboxylesterase-1 in Hepatocellular Carcinoma Cells Using Ag–Au Nanoflowers as SERS Substrate},
  journal = {Analytical Chemistry},
  year = {2024},
  volume = {96},
  number = {46},
  pages = {18555--18563},
  doi = {10.1021/acs.analchem.4c04763}
}
Kostenlos starten →