Electrochemiluminescence Biosensor for Ascorbic Acid Based on Target Transformation of Cell-Free RNA Transcription System and Duplex-Specific Nuclease-Assisted Recycling Amplification
Analytical Chemistry · 2024
DOI: 10.1021/acs.analchem.4c04206 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2024. Verfasst von Ming Chen und 7 weiteren Autor:innen. Beteiligte Einrichtung: Ministry of Education Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection fo…. Hauptthemen laut MEDLINE: Biosensing Techniques, Ascorbic Acid, Electrochemical Techniques, Luminescent Measurements. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 28 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Cooperative Project of Production and Study in University of Fujian Province.
Abstract (Originalsprache)
A cell-free RNA transcription system had been coupled with electrochemiluminescence (ECL) detection technology for the first time to develop an ascorbic acid (AA, acting as a model target) biosensor. The biosensor is composed of single-stranded DNA (ssDNA) sequences modified with alkynyl and azido groups, respectively, alongside an incomplete gene circuit framework. The addition of target AA and copper ions will cause the linkage of the two ssDNA sequences through a click chemistry reaction. This results in the subsequent reconstruction of a complete gene circuit. The reconstituted gene circuit, in conjunction with the T7 RNA polymerase, drives the transcription of substantial quantities of RNA. ssDNA labeled with ferrocene (Fc) (Fc-DNA) had been immobilized on a tris(2,2'-bipyridyl) ruthenium(II) chloride hexahydrate-doped SiO2 nanoparticle (Ru@SiO2 NPs) modified electrode first. The quenching effect of Fc on Ru@SiO2 causes the low ECL detected. The transcribed RNA sequence assisted double-stranded specific nuclease (DSN) to cut the ssDNA-Fc and the ECL of the system was enhanced. Optimal experimental conditions reveal that the ECL signal exhibits a linear correlation with the logarithmic concentration of AA, spanning a detection range from 100 nM to 1 mM, with a detection limit of 45 nM. This innovative methodology expands the utility of a cell-free RNA transcription system within the realm of biosensing applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Ministry of Education Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian…
- Department of Thoracic Oncology, Clinical Oncology School of Fujian Medical University, Fujian Cancer Hospital (Fujian Branch of Fudan University Shanghai Cancer Center), No. 420 Fuma Road, Fuzhou, Fujian 350014, China.
ORCID-Profile: Fang Luo, Jian Wang, Bin Qiu, Zhenyu Lin
Förderung
- National Natural Science Foundation of China
- Cooperative Project of Production and Study in University of Fujian Province
Zitieren
APA
Chen, M., Zeng, H., Luo, F., Huang, Y., Lin, C., Wang, J., Qiu, B., & Lin, Z. (2024). Electrochemiluminescence Biosensor for Ascorbic Acid Based on Target Transformation of Cell-Free RNA Transcription System and Duplex-Specific Nuclease-Assisted Recycling Amplification. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c04206
Vancouver
Chen M, Zeng H, Luo F, Huang Y, Lin C, Wang J, et al. Electrochemiluminescence Biosensor for Ascorbic Acid Based on Target Transformation of Cell-Free RNA Transcription System and Duplex-Specific Nuclease-Assisted Recycling Amplification. Analytical Chemistry. 2024. doi:10.1021/acs.analchem.4c04206
BibTeX
@article{Chen2024,
author = {Chen, Ming and Zeng, Hongfu and Luo, Fang and Huang, Yunjian and Lin, Cuiying and Wang, Jian and Qiu, Bin and Lin, Zhenyu},
title = {Electrochemiluminescence Biosensor for Ascorbic Acid Based on Target Transformation of Cell-Free RNA Transcription System and Duplex-Specific Nuclease-Assisted Recycling Amplification},
journal = {Analytical Chemistry},
year = {2024},
doi = {10.1021/acs.analchem.4c04206}
}
EUVIMED