EUVIMEDEUVIMED entdecken
Crossref

Point-of-Care Diagnosis of Tuberculosis Using a Portable Nucleic Acid Test with Distance-Based Readout

Tianyu Dong, Liwen Qin, Zhiyin Wang, Chen Fan, Chenlan Shen, Pin Feng, Qingquan Kong, Bowen Ke iD, Binwu Ying iD, Feng Li iD

Analytical Chemistry · 2024

DOI: 10.1021/acs.analchem.4c04180 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2024. Verfasst von Tianyu Dong und 9 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Green Chemistry and Technology of Ministry of Education, College of Chemistry, Sichuan University, Chengdu 610064, P. R. China. Hauptthemen laut MEDLINE: Nucleic Acid Amplification Techniques, Tuberculosis, Mycobacterium tuberculosis, Point-of-Care Systems. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Science and Technology Department of Tibet Autonomous Region, Sichuan University, Chengdu Municipal Science and Technology Program.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Rapid and accurate diagnosis of tuberculosis (TB) infection in resource-limited settings is critically needed to stop the spread of the disease but remains difficult to achieve. Herein, we report a fast, inexpensive nucleic acid test with distance-based readout (FINDR) for TB. Based on the unique chromatographic behavior of DNA intercalating dye on unmodified cellulose paper, our FINDR platform converted the amplicons of loop-mediated isothermal amplification (LAMP) into the migration distance on a paper-based analytical device. A suite of innovations were further introduced to enhance the accessibility of FINDR, including (1) screening optimal LAMP primers for distance-based readout; (2) developing a chip-on-cover design capable of streamlining LAMP amplification and distance-based detection in a fully sealed FINDR chip with a simple hand-based swirling for liquid transfer; and (3) integrating FINDR with an upstream portable pipetting-free DNA extractor and a downstream smartphone app to simplify sample processing and data interpretation. With these innovations, FINDR demonstrated a high clinical sensitivity (96.6%) and specificity (100%) upon validation against clinical sputum samples. Successful clinical validation was also achieved when FINDR was deployed as a point-of-care test for detecting TB under resource-limited conditions.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Nucleic Acid Amplification TechniquesTuberculosisMycobacterium tuberculosisPoint-of-Care SystemsHumansMolecular Diagnostic TechniquesDNA, BacterialPoint-of-Care Testing

Substanzen

DNA, Bacterial

Autor:innen und Institutionen

  • Key Laboratory of Green Chemistry and Technology of Ministry of Education, College of Chemistry, Sichuan University, Chengdu 610064, P. R. China.
  • Laboratory of Anesthesiology & Critical Care Medicine, Department of Anesthesiology, West China Hospital, Sichuan University, Chengdu 610041, P. R. China.
  • Department of Orthopedics Surgery, Hospital of Chengdu Office of People's Government of Tibetan Autonomous Region, Chengdu 610041, P. R. China.
  • Department of Laboratory Medicine, Med+X Center for Manufacturing, West China Hospital, Sichuan University, Chengdu 610041, P. R. China.
  • Department of Orthopedics, West China Hospital, Sichuan University, Chengdu 610041, P. R. China.

ORCID-Profile: Bowen Ke, Binwu Ying, Feng Li

Förderung

  • Science and Technology Department of Tibet Autonomous Region
  • Sichuan University
  • Chengdu Municipal Science and Technology Program
  • National Natural Science Foundation of China

Zitieren

APA

Dong, T., Qin, L., Wang, Z., Fan, C., Shen, C., Feng, P., Kong, Q., Ke, B., Ying, B., & Li, F. (2024). Point-of-Care Diagnosis of Tuberculosis Using a Portable Nucleic Acid Test with Distance-Based Readout. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c04180

Vancouver

Dong T, Qin L, Wang Z, Fan C, Shen C, Feng P, et al. Point-of-Care Diagnosis of Tuberculosis Using a Portable Nucleic Acid Test with Distance-Based Readout. Analytical Chemistry. 2024. doi:10.1021/acs.analchem.4c04180

BibTeX
@article{Dong2024,
  author = {Dong, Tianyu and Qin, Liwen and Wang, Zhiyin and Fan, Chen and Shen, Chenlan and Feng, Pin and Kong, Qingquan and Ke, Bowen and Ying, Binwu and Li, Feng},
  title = {Point-of-Care Diagnosis of Tuberculosis Using a Portable Nucleic Acid Test with Distance-Based Readout},
  journal = {Analytical Chemistry},
  year = {2024},
  doi = {10.1021/acs.analchem.4c04180}
}
Kostenlos starten →