Development of a Semiquantitative Barcode Readout Approach for Paper-Based Analytical Devices (PADs) for Enzymatic H 2 O 2 and Glucose Detection
Analytical Chemistry · 28.01.2025 · 97 (3) · 1500-1506
DOI: 10.1021/acs.analchem.4c04113 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 10.01.2025. Verfasst von Yanawut Manmana und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan. Hauptthemen laut MEDLINE: Hydrogen Peroxide, Paper, Glucose, Biosensing Techniques. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: Japan Society for the Promotion of Science.
Abstract (Originalsprache)
High Resolution Image Download MS PowerPoint Slide The integration of barcode technology with smartphones on paper-based analytical devices (PADs) presents a promising approach to bridging manual detection with digital interpretation and data storage. However, previous studies of 1D barcode approaches have been limited to providing only a “yes/no” response for analyte detection. Herein, a method of using barcode readout for semiquantitative signal detection on PADs has been achieved through the integration of barcode technology with a distance-based measurement concept on PADs. To demonstrate the feasibility of this concept, a PAD fabrication strategy incorporating barcodes was explored, using the enzymatic reaction between horseradish peroxidase (HRP), 3,3′-diaminobenzidine (DAB), and H 2 O 2 as a model system. The enzyme-catalyzed polymerization of DAB to polyDAB in the presence of hydrogen peroxide results in the appearance of color observable by the naked eye inside a paperfluidic channel, with the color-changed length depending on the H 2 O 2 concentration. At the same time, the barcode pattern displayed as a result of this distance-based color evolution overlaid with a paper-based barcode layer can be read using a smartphone application. Parameters affecting the signal readout performance were studied. The developed device can be used to detect H 2 O 2 concentrations in the range of 0.25 to 10 mM within 90 min with 79.6% of barcode signals correctly readable. Additionally, results from different smartphone models showed a consistent reading performance (78.4–79.6%). Finally, the quantification of glucose levels in artificial urine samples was demonstrated. This developed PAD signaling strategy offers end-users more simplicity and can be used as a standalone device or in conjunction with other digital devices.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Applied Chemistry, Keio University, 3-14-1 Hiyoshi, Kohoku-ku, Yokohama 223-8522, Japan.
ORCID-Profile: Yanawut Manmana, Yuki Hiruta, Daniel Citterio
Förderung
- Japan Society for the Promotion of Science
Zitieren
APA
Manmana, Y., Kinugasa, S., Hiruta, Y., & Citterio, D. (2025). Development of a Semiquantitative Barcode Readout Approach for Paper-Based Analytical Devices (PADs) for Enzymatic H 2 O 2 and Glucose Detection. Analytical Chemistry, 97(3), 1500-1506. https://doi.org/10.1021/acs.analchem.4c04113
Vancouver
Manmana Y, Kinugasa S, Hiruta Y, Citterio D. Development of a Semiquantitative Barcode Readout Approach for Paper-Based Analytical Devices (PADs) for Enzymatic H 2 O 2 and Glucose Detection. Analytical Chemistry. 2025;97(3):1500-1506. doi:10.1021/acs.analchem.4c04113
BibTeX
@article{Manmana2025,
author = {Manmana, Yanawut and Kinugasa, Shuma and Hiruta, Yuki and Citterio, Daniel},
title = {Development of a Semiquantitative Barcode Readout Approach for Paper-Based Analytical Devices (PADs) for Enzymatic H 2 O 2 and Glucose Detection},
journal = {Analytical Chemistry},
year = {2025},
volume = {97},
number = {3},
pages = {1500--1506},
doi = {10.1021/acs.analchem.4c04113}
}