Ultrasensitive Electrochemical Biosensor with Powerful Triple Cascade Signal Amplification for Detection of MicroRNA
Analytical Chemistry · 17.09.2024 · 96 (37) · 15066-15073
DOI: 10.1021/acs.analchem.4c03766 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 03.09.2024. Verfasst von Xin Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engine…. Hauptthemen laut MEDLINE: MicroRNAs, Biosensing Techniques, Electrochemical Techniques, DNA, Catalytic. Die Arbeit wurde bisher 46-mal zitiert (Crossref) und nennt 33 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.
Abstract (Originalsprache)
In this work, by ingeniously integrating catalytic hairpin assembly (CHA), double-end Mg2+-dependent DNAzyme, and hybridization chain reaction (HCR) as a triple cascade signal amplifier, an efficient concatenated CHA-DNAzyme-HCR (CDH) system was constructed to develop an ultrasensitive electrochemical biosensor with a low-background signal for the detection of microRNA-221 (miRNA-221). In the presence of the target miRNA-221, the CHA cycle was initiated by reacting with hairpins H1 and H2 to form DNAzyme structure H1-H2, which catalyzed the cleavage of the substrate hairpin H0 to release two output DNAs (output 1 and output 2). Subsequently, the double-loop hairpin H fixed on the electrode plate was opened by the output DNAs, to trigger the HCR with the assistance of hairpins Ha and Hb. Finally, methylene blue was intercalated into the long dsDNA polymer of the HCR product, resulting in a significant electrochemical signal. Surprisingly, the double-loop structure of the hairpin H could prominently reduce the background signal for enhancing the signal-to-noise ratio (S/N). As a proof of concept, an ultrasensitive electrochemical biosensor was developed using the CDH system with a detection limit as low as 9.25 aM, achieving favorable application for the detection of miRNA-221 in various cancer cell lysates. Benefiting from its enzyme-free, label-free, low-background, and highly sensitive characteristics, the CDH system showed widespread application potential for analyzing trace amounts of biomarkers in various clinical research studies.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
ORCID-Profile: Ya-Qin Chai, Ruo Yuan
Förderung
- Fundamental Research Funds for the Central Universities
- National Natural Science Foundation of China
Zitieren
APA
Wang, X., Liu, W. W., Long, L. L., Tan, S. Y., Chai, Y. Q., & Yuan, R. (2024). Ultrasensitive Electrochemical Biosensor with Powerful Triple Cascade Signal Amplification for Detection of MicroRNA. Analytical Chemistry, 96(37), 15066-15073. https://doi.org/10.1021/acs.analchem.4c03766
Vancouver
Wang X, Liu WW, Long LL, Tan SY, Chai YQ, Yuan R. Ultrasensitive Electrochemical Biosensor with Powerful Triple Cascade Signal Amplification for Detection of MicroRNA. Analytical Chemistry. 2024;96(37):15066-15073. doi:10.1021/acs.analchem.4c03766
BibTeX
@article{Wang2024,
author = {Wang, Xin and Liu, Wei-Wei and Long, Lin-Lin and Tan, Song-Yuan and Chai, Ya-Qin and Yuan, Ruo},
title = {Ultrasensitive Electrochemical Biosensor with Powerful Triple Cascade Signal Amplification for Detection of MicroRNA},
journal = {Analytical Chemistry},
year = {2024},
volume = {96},
number = {37},
pages = {15066--15073},
doi = {10.1021/acs.analchem.4c03766}
}
EUVIMED