Selenium Hydride-Induced Oxidase-like Activity Inhibition of Amorphous/Crystalline Manganese Dioxide: Colorimetric Assay for Selenium Detection
Analytical Chemistry · 26.11.2024 · 96 (47) · 18718-18726
DOI: 10.1021/acs.analchem.4c03738 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 12.11.2024. Verfasst von Bodong Wang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Green Chemistry & Technology, Ministry of Education, College of Chemistry, Sichuan University, Chengdu, Sichuan 610064, China. Hauptthemen laut MEDLINE: Oxides, Manganese Compounds, Colorimetry, Selenium. Die Arbeit wurde bisher 31-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China, Higher Education Discipline Innovation Project.
Abstract (Originalsprache)
Hydride generation-based optical sensors have achieved on-site visual selenium (Se) determination with high anti-interference capability, yet they rely on the change of single-color intensity with a narrow linear dynamic range. Herein, we combined selenium hydride (H2Se)-induced activity inhibition of a manganese dioxide (MnO2) nanozyme with different degrees of 3,3',5,5'-tetramethylbenzidine (TMB) oxidation to realize sensitive multicolor visual detection of Se(IV). Due to its high oxidase-like (OXD-like) activity and sensitive response to H2Se, amorphous/crystalline manganese dioxide (ac-MnO2) was selected to form the headspace single droplet for microextraction and recognition. Via headspace redox reaction with H2Se, ac-MnO2 was reduced into low valence accompanied by in situ generation of Se nanoparticles, leading to the formation of a Se-MnOx aggregate. The experimental results and theoretical calculation indicated that, compared with MnO2, Se-MnOx had decreased active sites for adsorbing O2 to generate •O2-, resulting in the nanozyme activity inhibition that was totally dependent on Se(IV) concentration. The implementation of this strategy enabled accurate Se(IV) detection with a linear range from 10 to 600 μg L-1 and a limit of detection of 1.8 μg L-1. The portable smartphone-based detection for real sample analysis further demonstrated that this assay can be an easy, convenient, and intelligent tool for on-site selenium determination.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Key Laboratory of Green Chemistry & Technology, Ministry of Education, College of Chemistry, Sichuan University, Chengdu, Sichuan 610064, China.
- Analytical & Testing Center, Sichuan University, Chengdu, Sichuan 610064, China.
ORCID-Profile: Xiandeng Hou, Kailai Xu
Förderung
- Fundamental Research Funds for the Central Universities
- National Natural Science Foundation of China
- Higher Education Discipline Innovation Project
Zitieren
APA
Wang, B., Pu, S., Ma, B., Zou, X., Xiong, Q., Hou, X., & Xu, K. (2024). Selenium Hydride-Induced Oxidase-like Activity Inhibition of Amorphous/Crystalline Manganese Dioxide: Colorimetric Assay for Selenium Detection. Analytical Chemistry, 96(47), 18718-18726. https://doi.org/10.1021/acs.analchem.4c03738
Vancouver
Wang B, Pu S, Ma B, Zou X, Xiong Q, Hou X, et al. Selenium Hydride-Induced Oxidase-like Activity Inhibition of Amorphous/Crystalline Manganese Dioxide: Colorimetric Assay for Selenium Detection. Analytical Chemistry. 2024;96(47):18718-18726. doi:10.1021/acs.analchem.4c03738
BibTeX
@article{Wang2024,
author = {Wang, Bodong and Pu, Shan and Ma, Bingxin and Zou, Xingyan and Xiong, Qing and Hou, Xiandeng and Xu, Kailai},
title = {Selenium Hydride-Induced Oxidase-like Activity Inhibition of Amorphous/Crystalline Manganese Dioxide: Colorimetric Assay for Selenium Detection},
journal = {Analytical Chemistry},
year = {2024},
volume = {96},
number = {47},
pages = {18718--18726},
doi = {10.1021/acs.analchem.4c03738}
}
EUVIMED