Electrochemical-Fluorescent Bimodal Biosensor Based on Dual CRISPR-Cas12a Multiple Cascade Amplification for ctDNA Detection
Analytical Chemistry · 27.08.2024 · 96 (34) · 14028-14035
DOI: 10.1021/acs.analchem.4c03012 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 12.08.2024. Verfasst von Hehua Zhang und 10 weiteren Autor:innen. Beteiligte Einrichtung: Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Natural Science Foundation of Heilongjiang Province, National Natural Science Foundation of China, Administration of Science & Technology Foundation of Mudanjiang.
Abstract (Originalsprache)
Circulating tumor DNA (ctDNA) is a critical biomarker for early tumor detection. However, accurately quantifying low-abundance ctDNA in human serum remains a significant challenge. To address this challenge, we introduce a bimodal biosensor tailored for detecting the epidermal growth factor receptor (EGFR) mutation L858R in specific nonsmall cell lung cancer (NSCLC) patients. This biosensor utilizes dual CRISPR-Cas12a systems to quantify the target via fluorescence and electrochemical signals. In our system, the EGFR L858R exhibits resistance to digestion by the restriction enzyme MscI, which activates the first CRISPR-Cas12a protein and inhibits the binding of magnetic beads with fluorescein (FAM)-labeled hybridization chain reaction (HCR) products, thereby reducing the fluorescence signal. This activation also inhibits the cleavage activity of the second CRISPR-Cas12a protein, allowing the electrode to sustain a higher electrochemical signal from nanomaterials. The wild-type EGFR (wt EGFR) produces the opposite effect. Consequently, the concentration of EGFR L858R can be accurately quantified and verified using both fluorescence and electrochemical signals. The biosensor offers a dynamic detection ranging from 10 fM to 1 μM, with a detection limit of 372 aM. It demonstrates excellent specificity, reproducibility, stability, and recovery rates. Moreover, the sensor’s enhanced analytical sensitivity highlights its critical role in biosensing applications and early disease diagnosis.
Autor:innen und Institutionen
- Collaborative Research Center, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China.
- School of Health Science and Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China.
- Public Health School, Mudanjiang Medical University, Mudanjiang 157011, China.
- The College of Medical Technology, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China.
- School of Pharmacy, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China.
- Department of Clinical Laboratory, the Affiliated Pudong Hospital, Fudan University, Shanghai 201399, China.
ORCID-Profile: Hongzhi Pan
Förderung
- Natural Science Foundation of Heilongjiang Province
- National Natural Science Foundation of China
- Administration of Science & Technology Foundation of Mudanjiang
- Shanghai Pudong Hospital
- Shanghai Pudong New Area
Zitieren
APA
Zhang, H., Gao, H., Mu, W., Que, L., Gu, X., Rong, S., Ma, H., Miao, M., Qi, X., Chang, D., & Pan, H. (2024). Electrochemical-Fluorescent Bimodal Biosensor Based on Dual CRISPR-Cas12a Multiple Cascade Amplification for ctDNA Detection. Analytical Chemistry, 96(34), 14028-14035. https://doi.org/10.1021/acs.analchem.4c03012
Vancouver
Zhang H, Gao H, Mu W, Que L, Gu X, Rong S, et al. Electrochemical-Fluorescent Bimodal Biosensor Based on Dual CRISPR-Cas12a Multiple Cascade Amplification for ctDNA Detection. Analytical Chemistry. 2024;96(34):14028-14035. doi:10.1021/acs.analchem.4c03012
BibTeX
@article{Zhang2024,
author = {Zhang, Hehua and Gao, Hongmin and Mu, Wendi and Que, Longbin and Gu, Xin and Rong, Shengzhong and Ma, Hongkun and Miao, Meng and Qi, Xue and Chang, Dong and Pan, Hongzhi},
title = {Electrochemical-Fluorescent Bimodal Biosensor Based on Dual CRISPR-Cas12a Multiple Cascade Amplification for ctDNA Detection},
journal = {Analytical Chemistry},
year = {2024},
volume = {96},
number = {34},
pages = {14028--14035},
doi = {10.1021/acs.analchem.4c03012}
}
EUVIMED