Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 23.09.2024. Verfasst von Xi Long und 6 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China. Hauptthemen laut MEDLINE: Escherichia coli O157, Nucleic Acid Amplification Techniques, Aptamers, Nucleotide, Milk. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Natural Science Foundation of Hunan Province, National Natural Science Foundation of China, State Key Laboratory of Chemo/Biosensing and Chemometrics, Hunan University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pathogens pose a serious threat to public and population health, leading to serious outbreak and spread of diseases irrespective of the region. The capability to directly, sensitively, and specifically detect viable pathogens in low numbers in food and clinical samples is very desirable but remains a challenge. In this work, we present a novel assay of a combination of an aptamer-based allosteric probe and hairpin switch-controlled T7 RNA polymerase-based isothermal transcription amplification, which enables rapid, ultrasensitive, label-free detection of direct pathogens. It can detect Escherichia coli as low as 73.2 CFU/mL. Moreover, with the usage of the proposed assay, sensitive quantification of E. coliO157:H7 in milk samples has been achieved, showing significant potential as a simple and sensitive tool to quantify pathogens in milk and other foods.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Escherichia coli O157Nucleic Acid Amplification TechniquesAptamers, NucleotideMilkDNA-Directed RNA PolymerasesAnimalsViral ProteinsLimit of DetectionBiosensing Techniques

Substanzen

Aptamers, NucleotideDNA-Directed RNA Polymerasesbacteriophage T7 RNA polymeraseViral Proteins

Autor:innen und Institutionen

  • College of Chemistry and Chemical Engineering, Central South University, Changsha 410083, China.
  • Hunan Provincial Key Laboratory of the Research and Development of Novel Pharmaceutical Preparations, the "Double-First Class" Application Characteristic Discipline of Hunan Province (Pharmaceutical Science), Changsha M…

ORCID-Profile: Yanjing Yang, Shian Zhong

Förderung

  • Natural Science Foundation of Hunan Province
  • National Natural Science Foundation of China
  • State Key Laboratory of Chemo/Biosensing and Chemometrics, Hunan University

Zitieren

APA

Long, X., Gong, Z., Gan, Y., Yuan, P., Tang, Y., Yang, Y., & Zhong, S. (2024). Sensitive Detection of Escherichia coli O157:H7 Using Allosteric Probe and Hairpin Switches-Based Isothermal Transcription Amplification. Analytical Chemistry, 96(39), 15608-15613. https://doi.org/10.1021/acs.analchem.4c02413

Vancouver

Long X, Gong Z, Gan Y, Yuan P, Tang Y, Yang Y, et al. Sensitive Detection of Escherichia coli O157:H7 Using Allosteric Probe and Hairpin Switches-Based Isothermal Transcription Amplification. Analytical Chemistry. 2024;96(39):15608-15613. doi:10.1021/acs.analchem.4c02413

BibTeX
@article{Long2024,
  author = {Long, Xi and Gong, Zan and Gan, Yuqing and Yuan, Panpan and Tang, Yalan and Yang, Yanjing and Zhong, Shian},
  title = {Sensitive Detection of Escherichia coli O157:H7 Using Allosteric Probe and Hairpin Switches-Based Isothermal Transcription Amplification},
  journal = {Analytical Chemistry},
  year = {2024},
  volume = {96},
  number = {39},
  pages = {15608--15613},
  doi = {10.1021/acs.analchem.4c02413}
}
Kostenlos starten →