EUVIMEDEUVIMED entdecken
Crossref

Automatic Electrochemiluminescence Method for the Detection of Cancerous Exosomes Incorporating Specific Aptamer-Magnetic Beads and Signal Nanoprobes

Xiaolin Yang iD, Lining Liu, Yanlong Feng iD, Xuan Guo, Yang Wu, Qiang Gao, Chengxiao Zhang iD, Honglan Qi iD

Analytical Chemistry · 2024

DOI: 10.1021/acs.analchem.4c01938 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, 2024. Verfasst von Xiaolin Yang und 7 weiteren Autor:innen. Beteiligte Einrichtung: Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University,…. Hauptthemen laut MEDLINE: Exosomes, Aptamers, Nucleotide, Electrochemical Techniques, Luminescent Measurements. Die Arbeit wurde bisher 22-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Exosomes, as an emerging biomarker, have exhibited remarkable promise in early cancer diagnosis. Here, a highly sensitive, selective, and automatic electrochemiluminescence (ECL) method for the detection of cancerous exosomes was developed. Specific aptamer-(EK)4 peptide-tagged magnetic beads (MBs-(EK)4-aptamer) were designed as a magnetic capture probe in which the (EK)4 peptide was used to reduce the steric binding hindrance of cancerous exosomes with a specific aptamer. One new universal ECL signal nanoprobe (CD9 Ab-PEG@SiO2ϵRu(bpy)32+) was designed and synthesized by using microporous SiO2 nanoparticles as the carrier for loading ECL reagent Ru(bpy)32+, polyethylene glycol (PEG) layer, and anticluster of differentiation 9 antibody (CD9 Ab). A "sandwich" biocomplex was formed on the surface of the magnetic capture probe after mixing the capture probe, target exosomes, and ECL signal nanoprobe, and then it was introduced into an automated ECL analyzer for rapid and automatic ECL measurement. It was found that the designed signal nanoprobe shows a 270-fold improvement in the signal-to-noise ratio than that of the ruthenium complex-labeled CD9 antibody signal probe. The relative ECL intensity was proportional to MCF-7 exosomes as a model in the range of 102 to 104 particle/μL, with a detection limit of 11 particle/μL. Furthermore, the ECL method was employed to discriminate cancerous exosomes based on fingerprint responses using the designed multiple magnetic capture probes and the universal ECL signal nanoprobe. This work demonstrates that the utilization of a designed automated ECL tactic using the MBs-(EK)4-aptamer capture probe and the CD9 Ab-PEG@SiO2ϵRu(bpy)32+ signal nanoprobe will provide a unique and robust method for the detection and discrimination of cancerous exosomes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ExosomesAptamers, NucleotideElectrochemical TechniquesLuminescent MeasurementsHumansMCF-7 CellsSilicon DioxideBiosensing TechniquesTetraspanin 29Polyethylene Glycols

Substanzen

Aptamers, NucleotideSilicon DioxideTetraspanin 29Polyethylene Glycols

Autor:innen und Institutionen

  • Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, P. R. China.
  • Changzhi People's Hospital, Changzhi 046000, P. R. China.

ORCID-Profile: Xiaolin Yang, Yanlong Feng, Chengxiao Zhang, Honglan Qi

Förderung

  • Fundamental Research Funds for the Central Universities
  • National Natural Science Foundation of China

Zitieren

APA

Yang, X., Liu, L., Feng, Y., Guo, X., Wu, Y., Gao, Q., Zhang, C., & Qi, H. (2024). Automatic Electrochemiluminescence Method for the Detection of Cancerous Exosomes Incorporating Specific Aptamer-Magnetic Beads and Signal Nanoprobes. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c01938

Vancouver

Yang X, Liu L, Feng Y, Guo X, Wu Y, Gao Q, et al. Automatic Electrochemiluminescence Method for the Detection of Cancerous Exosomes Incorporating Specific Aptamer-Magnetic Beads and Signal Nanoprobes. Analytical Chemistry. 2024. doi:10.1021/acs.analchem.4c01938

BibTeX
@article{Yang2024,
  author = {Yang, Xiaolin and Liu, Lining and Feng, Yanlong and Guo, Xuan and Wu, Yang and Gao, Qiang and Zhang, Chengxiao and Qi, Honglan},
  title = {Automatic Electrochemiluminescence Method for the Detection of Cancerous Exosomes Incorporating Specific Aptamer-Magnetic Beads and Signal Nanoprobes},
  journal = {Analytical Chemistry},
  year = {2024},
  doi = {10.1021/acs.analchem.4c01938}
}
Kostenlos starten →