Development of a Methodology Based on Optical Interferometry for Measuring Fibrinolytic Activity
Analytical Chemistry · 2024
DOI: 10.1021/acs.analchem.4c01646 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2024. Verfasst von Liming Liu und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, Chin…. Hauptthemen laut MEDLINE: Interferometry, Fibrinolysis, Fibrin. Die Arbeit wurde bisher 13-mal zitiert (Crossref) und nennt 46 Literaturangaben. Gefördert von: Jiangsu Provincial Key Research and Development Program, Leading Talent Program for Gusu Innovation and Entrepreneurship in Suzhou.
Abstract (Originalsprache)
Fibrinolytic activity assay is particularly important for the detection, diagnosis, and treatment of cardiovascular disease and the development of fibrinolytic drugs. A novel efficacious strategy for real-time and label-free dynamic detection of fibrinolytic activity based on ordered porous layer interferometry (OPLI) was developed. Fibrin or a mixture of fibrin and plasminogen (Plg) was loaded into the highly ordered silica colloidal crystal (SCC) film scaffold to construct a fibrinolytic response interference layer to measure fibrinolytic activity with different mechanisms of action. Fibrinolytic enzyme-triggered fibrinolysis led to the migration of interference fringes in the interferogram, which could be represented by optical thickness changes (ΔOT) tracked in real time by the OPLI system. The morphology and optical property of the fibrinolytic response interference layer were characterized, and the Plg content in the fibrinolytic response interference layer and experimental parameters of the system were optimized. The method showed adequate sensitivity for the fibrinolytic activity of lumbrokinase and streptokinase, with wide linear ranges of 12-6000 and 10-2000 U/mL, respectively. Compared with the traditional fibrin plate method, it has a lower detection limit and higher linearity. The whole kinetic process of fibrinolysis by these two fibrinolytic drug models was recorded in real time, and the Michaelis constant and apparent kinetic parameters were calculated. Importantly, some other blood proteins were less interfering with this system, and it showed reliability in fibrin activity detection in real whole blood samples. This study established a better and more targeted research method of in vitro fibrinolysis and provided dynamic monitoring data for the analysis of fibrinolytic activity of whole blood.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Digital Medical Engineering, School of Biological Science and Medical Engineering, Southeast University, Nanjing 210096, China.
- OPLI (Suzhou) Biotechnology Company Limited, New District, Suzhou 215163, China.
ORCID-Profile: Yu Zhang, Yi-Zhen Wan, Weiping Qian
Förderung
- Jiangsu Provincial Key Research and Development Program
- Leading Talent Program for Gusu Innovation and Entrepreneurship in Suzhou
Zitieren
APA
Liu, L., Ma, N., Wang, L., Zhang, Y., Wan, Y. Z., Wang, T., & Qian, W. (2024). Development of a Methodology Based on Optical Interferometry for Measuring Fibrinolytic Activity. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c01646
Vancouver
Liu L, Ma N, Wang L, Zhang Y, Wan YZ, Wang T, et al. Development of a Methodology Based on Optical Interferometry for Measuring Fibrinolytic Activity. Analytical Chemistry. 2024. doi:10.1021/acs.analchem.4c01646
BibTeX
@article{Liu2024,
author = {Liu, Liming and Ma, Ning and Wang, Lu and Zhang, Yu and Wan, Yi-Zhen and Wang, Tianze and Qian, Weiping},
title = {Development of a Methodology Based on Optical Interferometry for Measuring Fibrinolytic Activity},
journal = {Analytical Chemistry},
year = {2024},
doi = {10.1021/acs.analchem.4c01646}
}
EUVIMED