Calibration-Free Analysis with Chronoamperometry at Microelectrodes
Analytical Chemistry · 17.09.2024 · 96 (37) · 14766-14774
DOI: 10.1021/acs.analchem.4c01645 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 03.09.2024. Verfasst von Valdomiro S Conceição und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo-USP, São Paulo, 05508-000, Brazil. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico, Funda??o de Amparo ? Pesquisa do Estado de S?o Paulo, Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior.
Abstract (Originalsprache)
Analytical methods are crucial for monitoring and assessing the concentration of important chemicals, and there is now a growing demand for methodologies that allow miniaturization, require lower sample volumes, and enable real-time analysis in the field. Most electroanalytical techniques depend on calibrations or standards, and this has several limitations, ranging from matrix interference, to stability problems, time required, cost and waste. Therefore, strategies that do not require standards or calibration curves greatly interest the analytical chemistry community. Here, we propose a new quantification method that does not rely on calibration and is only based on a single chronoamperometric curve recorded with a microelectrode. We show that satisfactory analytical information is obtained with just one chronoamperometric experiment that only takes a few seconds. We propose different data treatments to determine the unknown concentration, we consider the experimental conditions and instrument parameters, we report how parallel reactions affect the results, and we recommend procedures to implement the method in autonomous sensors. We also show that the concentration of several species can be derived if their E° values are sufficiently far apart or the sum of all concentrations if the E° values are too close. The proposed method was validated with a model redox system then further evaluated by determining ascorbic acid concentrations in standard solutions and food supplements, and paracetamol in a pain killer. The results for ascorbic acid were compared with those obtained by coulometry, and a good agreement was found, with a maximum deviation ca. 10.8%. The approach was also successfully applied to ascorbic acid quantification in solutions with different viscosity using ethylene glycol as a thickener.
Autor:innen und Institutionen
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo-USP, São Paulo, 05508-000, Brazil.
- School of Chemistry, University of Southampton, Highfield, Southampton SO17 1BJ, U.K.
ORCID-Profile: Valdomiro S Conceição, Douglas P M Saraiva, Mauro Bertotti
Förderung
- Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico
- Funda??o de Amparo ? Pesquisa do Estado de S?o Paulo
- Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior
Zitieren
APA
Conceição, V. S., Saraiva, D. P. M., Denuault, G., & Bertotti, M. (2024). Calibration-Free Analysis with Chronoamperometry at Microelectrodes. Analytical Chemistry, 96(37), 14766-14774. https://doi.org/10.1021/acs.analchem.4c01645
Vancouver
Conceição VS, Saraiva DPM, Denuault G, Bertotti M. Calibration-Free Analysis with Chronoamperometry at Microelectrodes. Analytical Chemistry. 2024;96(37):14766-14774. doi:10.1021/acs.analchem.4c01645
BibTeX
@article{Conceio2024,
author = {Conceição, Valdomiro S and Saraiva, Douglas P M and Denuault, Guy and Bertotti, Mauro},
title = {Calibration-Free Analysis with Chronoamperometry at Microelectrodes},
journal = {Analytical Chemistry},
year = {2024},
volume = {96},
number = {37},
pages = {14766--14774},
doi = {10.1021/acs.analchem.4c01645}
}
EUVIMED