A Fully Automated Online Enrichment and Separation System for Highly Reproducible and In-Depth Analysis of Intact Glycopeptide
Analytical Chemistry · 2024
DOI: 10.1021/acs.analchem.4c01454 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, 2024. Verfasst von Zhonghan Hu und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningb…. Hauptthemen laut MEDLINE: Glycopeptides. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 43 Literaturangaben. Gefördert von: National Key Research and Development Program of China, K. C. Wong Magna Fund in Ningbo University, National Natural Science Foundation of China.
Abstract (Originalsprache)
A fully automated online enrichment and separation system for intact glycopeptides, named AutoGP, was developed in this study by integrating three different columns in a nano-LC system. Specifically, the peptide mixture from the enzymatic digestion of a complex biological sample was first loaded on a hydrophilic interaction chromatography (HILIC) column. The nonglycopeptides in the sample were washed off the column, and the glycopeptides retained by the HILIC column were eluted to a C18 trap column to achieve an automated glycopeptide enrichment. The enriched glycopeptides were further eluted to a C18 column for separation, and the separated glycopeptides were eventually analyzed by using an orbitrap mass spectrometer (MS). The optimal operating conditions for AutoGP were systemically studied, and the performance of the fully optimized AutoGP was compared with a conventional manual system used for glycopeptide analysis. The experimental evaluation shows that the total number of glycopeptides identified is at least 1.5-fold higher, and the median coefficient of variation for the analyses is at least 50% lower by using AutoGP, as compared to the results acquired by using the manual system. In addition, AutoGP can perform effective analysis even with a 1-μg sample amount, while a 10-μg sample at least will be needed by the manual system, implying an order of magnitude better sensitivity of AutoGP. All the experimental results have consistently proven that AutoGP can be used for much better characterization of intact glycopeptides.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Institute of Mass Spectrometry, Zhejiang Engineering Research Center of Advanced Mass Spectrometry and Clinical Application, Ningbo University, Ningbo 315211, PR China.
- Zhenhai Institute of Mass Spectrometry, Ningbo 315211, PR China.
- School of Material Science and Chemical Engineering, Ningbo University, Ningbo 315211, PR China.
Förderung
- National Key Research and Development Program of China
- K. C. Wong Magna Fund in Ningbo University
- National Natural Science Foundation of China
- Natural Science Foundation of Zhejiang Province
- Zhejiang Province
- Ningbo Science and Technology Project
- Yangtze River Delta Science and Technology Innovation Community Joint Research Project
Zitieren
APA
Hu, Z., Liu, R., Gao, W., Li, J., Wang, H., & Tang, K. (2024). A Fully Automated Online Enrichment and Separation System for Highly Reproducible and In-Depth Analysis of Intact Glycopeptide. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.4c01454
Vancouver
Hu Z, Liu R, Gao W, Li J, Wang H, Tang K. A Fully Automated Online Enrichment and Separation System for Highly Reproducible and In-Depth Analysis of Intact Glycopeptide. Analytical Chemistry. 2024. doi:10.1021/acs.analchem.4c01454
BibTeX
@article{Hu2024,
author = {Hu, Zhonghan and Liu, Rong and Gao, Wenqing and Li, Junhui and Wang, Hongxia and Tang, Keqi},
title = {A Fully Automated Online Enrichment and Separation System for Highly Reproducible and In-Depth Analysis of Intact Glycopeptide},
journal = {Analytical Chemistry},
year = {2024},
doi = {10.1021/acs.analchem.4c01454}
}
EUVIMED