Ratiometric Near-Infrared Fluorescent Probe Monitors Ferroptosis in HCC Cells by Imaging HClO in Mitochondria
Analytical Chemistry · 16.04.2024 · 96 (15) · 5992-6000
DOI: 10.1021/acs.analchem.4c00328 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 04.04.2024. Verfasst von Bo Zhao und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shandong 250022, China. Hauptthemen laut MEDLINE: Carcinoma, Hepatocellular, Ferroptosis, Liver Neoplasms. Die Arbeit wurde bisher 94-mal zitiert (Crossref) und nennt 55 Literaturangaben. Gefördert von: National Research Foundation of Korea, University of Jinan, Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
Hypochlorous acid (HClO) is a typical endogenous ROS produced mainly in mitochondria, and it has strong oxidative properties. Abnormal HClO levels lead to mitochondrial dysfunction, strongly associated with various diseases. It has been shown that HClO shows traces of overexpression in cells of both ferroptosis and hepatocellular carcinoma (HCC). Therefore, visualization of HClO levels during ferroptosis of HCC is important to explore its physiological and pathological roles. So far, there has been no report on the visualization of HClO in ferroptosis of HCC. Thus, we present a ratiometric near-infrared (NIR) fluorescent probe Mito-Rh-S which visualized for the first time the fluctuation of HClO in mitochondria during ferroptosis of HCC. Mito-Rh-S has an ultrafast response rate (2 s) and large emission shift (115 nm). Mito-Rh-S was constructed based on the PET sensing mechanism and thus has a high signal-to-noise ratio. The cell experiments of Mito-Rh-S demonstrated that Fe2+- and erastin-induced ferroptosis in HepG2 cells resulted in elevated levels of mitochondrial HClO and that high concentration levels of Fe2+ and erastin cause severe mitochondrial damage and oxidative stress and had the potential to kill HepG2 cells. By regulating the erastin concentration, erastin induction time, and treatment of the ferroptosis model, Mito-Rh-S can accurately detect the fluctuation of mitochondrial HClO levels during ferroptosis in HCC.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- School of Chemistry and Chemical Engineering, University of Jinan, Jinan, Shandong 250022, China.
- Shandong Anshun Pharmaceutical Company, Limited, Laoling, Shandong 253600, China.
- Department of Chemistry and Nanoscience, Ewha Womans University, Seoul 03760, South Korea.
ORCID-Profile: Juyoung Yoon, Zhengliang Lu
Förderung
- National Research Foundation of Korea
- University of Jinan
- Natural Science Foundation of Shandong Province
Zitieren
APA
Zhao, B., Xu, X., Wen, X., Liu, Q., Dong, C., Yang, Q., Fan, C., Yoon, J., & Lu, Z. (2024). Ratiometric Near-Infrared Fluorescent Probe Monitors Ferroptosis in HCC Cells by Imaging HClO in Mitochondria. Analytical Chemistry, 96(15), 5992-6000. https://doi.org/10.1021/acs.analchem.4c00328
Vancouver
Zhao B, Xu X, Wen X, Liu Q, Dong C, Yang Q, et al. Ratiometric Near-Infrared Fluorescent Probe Monitors Ferroptosis in HCC Cells by Imaging HClO in Mitochondria. Analytical Chemistry. 2024;96(15):5992-6000. doi:10.1021/acs.analchem.4c00328
BibTeX
@article{Zhao2024,
author = {Zhao, Bo and Xu, Xionghao and Wen, Xin and Liu, Qingqing and Dong, Chao and Yang, Qingkun and Fan, Chunhua and Yoon, Juyoung and Lu, Zhengliang},
title = {Ratiometric Near-Infrared Fluorescent Probe Monitors Ferroptosis in HCC Cells by Imaging HClO in Mitochondria},
journal = {Analytical Chemistry},
year = {2024},
volume = {96},
number = {15},
pages = {5992--6000},
doi = {10.1021/acs.analchem.4c00328}
}
EUVIMED