Microfluidic Immunosensing Platform Based on a Rolling Circle Amplification-Assisted DNA Dendrimer Probe for Portable and Sensitive Detection of Allergen-Specific IgE
Analytical Chemistry · 09.04.2024 · 96 (14) · 5625-5632
DOI: 10.1021/acs.analchem.4c00255 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 01.04.2024. Verfasst von Yiyu Chen und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Materials Science and Engineering, Huaqiao University, Xiamen 361021, China. Hauptthemen laut MEDLINE: Microfluidics, Dendrimers. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Natural Science Foundation of Fujian Province, Graphene Powder and Composite Research Center of Fujian Province, National Natural Science Foundation of China.
Abstract (Originalsprache)
The robust point-of-care platform for sensitive, multiplexed, and affordable detection of allergen-specific IgE (sIgE) is an urgent demand in component-resolved diagnostics. Here, we developed a microfluidic immunosensing platform based on a rolling circle amplification-assisted DNA dendrimer probe for sensitive detection of multiple sIgEs. The versatile multichannel microfluidic whole blood analytical device integrates cell filtration, recombinant antigen-modified magnetic enrichment, and DNA dendrimer probe-amplified signal transduction for portable on-chip analysis. Three sIgEs against common oyster allergens were simultaneously detected in blood samples by simple smartphone-based imaging without any pretreatment. The quantitative detection of multiple allergen-specific antibodies on the platform was achieved with limits of detection of less than 50 pg/mL, exhibiting superior sensitivity compared to most point-of-care testing. The detection results of 55 serum samples and 4 whole blood samples were 100% consistent with the ELISA results, confirming the accuracy and stability of our platform. Additionally, the reversible combination of hexahistidine6-tag and Ni-IMAC magbead was elegantly utilized on the immunosensing platform for desired reversibility. With the advantages of general applicability, high sensitivity, and reversibility, the DNA dendrimer-based microfluidic immunosensing platform provides great potential for the portable detection of immune proteins as a point-of-care platform in disease diagnostics and biological analysis.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- College of Materials Science and Engineering, Huaqiao University, Xiamen 361021, China.
- Key Laboratory of Molecular Designing and Green Conversions, Huaqiao University, Xiamen 361021, China.
- College of Ocean Food and Biological Engineering, Jimei University, Xiamen 361021, China.
- Xiamen Key Laboratory of Optoelectronic Materials and Advanced Manufacturing, Huaqiao University, Xiamen 361021, China.
ORCID-Profile: Bin Liu, Xiaofeng Wei
Förderung
- Natural Science Foundation of Fujian Province
- Graphene Powder and Composite Research Center of Fujian Province
- National Natural Science Foundation of China
Zitieren
APA
Chen, Y., He, S., Lian, H., Liu, G., Liu, B., & Wei, X. (2024). Microfluidic Immunosensing Platform Based on a Rolling Circle Amplification-Assisted DNA Dendrimer Probe for Portable and Sensitive Detection of Allergen-Specific IgE. Analytical Chemistry, 96(14), 5625-5632. https://doi.org/10.1021/acs.analchem.4c00255
Vancouver
Chen Y, He S, Lian H, Liu G, Liu B, Wei X. Microfluidic Immunosensing Platform Based on a Rolling Circle Amplification-Assisted DNA Dendrimer Probe for Portable and Sensitive Detection of Allergen-Specific IgE. Analytical Chemistry. 2024;96(14):5625-5632. doi:10.1021/acs.analchem.4c00255
BibTeX
@article{Chen2024,
author = {Chen, Yiyu and He, Shan and Lian, Huiting and Liu, Guangming and Liu, Bin and Wei, Xiaofeng},
title = {Microfluidic Immunosensing Platform Based on a Rolling Circle Amplification-Assisted DNA Dendrimer Probe for Portable and Sensitive Detection of Allergen-Specific IgE},
journal = {Analytical Chemistry},
year = {2024},
volume = {96},
number = {14},
pages = {5625--5632},
doi = {10.1021/acs.analchem.4c00255}
}
EUVIMED