High-Throughput Capillary Liquid Chromatography Using a Droplet Injection and Application to Reaction Screening
Analytical Chemistry · 19.03.2024 · 96 (11) · 4693-4701
DOI: 10.1021/acs.analchem.4c00150 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 05.03.2024. Verfasst von Yue Xin und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIDDK NIH HHS, NIGMS NIH HHS, Division of Chemistry.
Abstract (Originalsprache)
The cycle time of a standard liquid chromatography (LC) system is the sum of the time for the chromatographic run and the autosampler injection sequence. Although LC separation times in the 1-10 s range have been demonstrated, injection sequences are commonly >15 s, limiting throughput possible with LC separations. Further, such separations are performed on relatively large bore columns requiring flow rates of ≥5 mL/min, thus generating large volumes of mobile phase waste when used for large scale screening and increasing the difficulty in interfacing to mass spectrometry. Here, a droplet injector system was established that replaces the autosampler with a four-port, two-position valve equipped with a 20 nL internal loop interfaced to a syringe pump and a three-axis positioner to withdraw sample droplets from a well plate. In the system, sample and immiscible fluid are pulled alternately from a well plate into a capillary and then through the injection valve. The valve is actuated when sample fills the loop to allow sequential injection of samples at high throughput. Capillary LC columns with 300 μm inner diameter were used to reduce the consumption of mobile phase and sample. The system achieved 96 separations of 20 nL droplet samples containing 3 components in as little as 8.1 min with 5-s cycle time. This system was coupled to a mass spectrometer through an electrospray ionization source for high-throughput chemical reaction screening.
Autor:innen und Institutionen
- Department of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.
- Department of Chemistry and Biochemistry, Rowan University, Glassboro, New Jersey 08028, United States.
- Pfizer Global Research and Development, Eastern Point Road, Groton, Connecticut 06415, United States.
- Department of Pharmacology, University of Michigan, Ann Arbor, Michigan 48109, United States.
ORCID-Profile: Devin M Makey, Simon Berritt, James P Grinias, Robert T Kennedy
Förderung
- NIDDK NIH HHS
- NIGMS NIH HHS
- Division of Chemistry
- Division of Graduate Education
- Pfizer
- National Institute of General Medical Sciences
Zitieren
APA
Xin, Y., Foster, S. W., Makey, D. M., Parker, D., Bradow, J., Wang, X., Berritt, S., Mongillo, R., Grinias, J. P., & Kennedy, R. T. (2024). High-Throughput Capillary Liquid Chromatography Using a Droplet Injection and Application to Reaction Screening. Analytical Chemistry, 96(11), 4693-4701. https://doi.org/10.1021/acs.analchem.4c00150
Vancouver
Xin Y, Foster SW, Makey DM, Parker D, Bradow J, Wang X, et al. High-Throughput Capillary Liquid Chromatography Using a Droplet Injection and Application to Reaction Screening. Analytical Chemistry. 2024;96(11):4693-4701. doi:10.1021/acs.analchem.4c00150
BibTeX
@article{Xin2024,
author = {Xin, Yue and Foster, Samuel W and Makey, Devin M and Parker, Deklin and Bradow, James and Wang, Xiaochun and Berritt, Simon and Mongillo, Robert and Grinias, James P and Kennedy, Robert T},
title = {High-Throughput Capillary Liquid Chromatography Using a Droplet Injection and Application to Reaction Screening},
journal = {Analytical Chemistry},
year = {2024},
volume = {96},
number = {11},
pages = {4693--4701},
doi = {10.1021/acs.analchem.4c00150}
}
EUVIMED