Near-Infrared Responsive Ag@Au Nanoplates with Exceptional Stability for Highly Sensitive Colorimetric and Photothermal Dual-Mode Lateral Flow Immunoassay
Analytical Chemistry · 05.02.2024
DOI: 10.1021/acs.analchem.3c05787 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 05.02.2024. Verfasst von Kun Wang und 5 weiteren Autor:innen. Beteiligte Einrichtung: College of Chemistry and Chemical Engineering, State Key Laboratory of Chemical Safety, China University of Petroleum (East China), Qingdao 266580, P…. Die Arbeit wurde bisher 18-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China, Natural Science Foundation of Shandong Province.
Abstract (Originalsprache)
Lateral flow immunoassay (LFIA) has played a vital role in point-of-care (POC) testing on account of its simplicity, rapidity, and low cost. However, the low sensitivity and difficulty of quantitation limit its further development. Sensitive markers with new detection modes are being developed to dramatically improve LFIA's performance. Herein, a ligand-complex approach was proposed to uniformly coat a thin layer of Au onto Ag triangular nanoplates (Ag TNPs) without etching the Ag cores, which not only retain the unique optical properties from Ag TNPs but also acquire the surface stability and biocompatibility of gold. The localized surface plasmon resonance absorption of these Ag@Au TNPs could be finely adjusted from visible (550 nm) to the second near-infrared region (NIR-II) (1100 nm), and even longer, by simply adjusting the ratio between edge length and thickness. Utilizing the Ag@Au TNPs as new markers for LFIA, a highly sensitive colorimetric and photothermal dual-mode detection of the SARS-CoV-2 nucleocapsid protein was achieved with a very low background. The Ag@Au TNPs showed an exceedingly high photothermal conversion efficiency of 61.4% (ca. 2 times higher than that of Au nanorods), endowing the LFIA method with a low photothermal detection limit (40 pg/mL), which was 25-fold lower than that of the colorimetric results. The generality of the method was further verified by the sensitive and accurate analysis of cardiac troponin I (cTnI). This method is robust, reproducible, and highly specific and has been successfully applied to SARS-COV-2 detection in 35 clinical samples with satisfactory results, demonstrating its potential for POC applications.
Autor:innen und Institutionen
- College of Chemistry and Chemical Engineering, State Key Laboratory of Chemical Safety, China University of Petroleum (East China), Qingdao 266580, P. R. China.
- Hubei Provincial Center for Disease Control and Prevention, Wuhan 430065, China.
ORCID-Profile: Cong-Ying Wen, Jingbin Zeng
Förderung
- Fundamental Research Funds for the Central Universities
- National Natural Science Foundation of China
- Natural Science Foundation of Shandong Province
- Science and Technology Projects of Qingdao
Zitieren
APA
Wang, K., Liu, X., Liang, X., Jiang, Y., Wen, C. Y., & Zeng, J. (2024). Near-Infrared Responsive Ag@Au Nanoplates with Exceptional Stability for Highly Sensitive Colorimetric and Photothermal Dual-Mode Lateral Flow Immunoassay. Analytical Chemistry. https://doi.org/10.1021/acs.analchem.3c05787
Vancouver
Wang K, Liu X, Liang X, Jiang Y, Wen CY, Zeng J. Near-Infrared Responsive Ag@Au Nanoplates with Exceptional Stability for Highly Sensitive Colorimetric and Photothermal Dual-Mode Lateral Flow Immunoassay. Analytical Chemistry. 2024. doi:10.1021/acs.analchem.3c05787
BibTeX
@article{Wang2024,
author = {Wang, Kun and Liu, Xiaohui and Liang, Xinyi and Jiang, Yongzhong and Wen, Cong-Ying and Zeng, Jingbin},
title = {Near-Infrared Responsive Ag@Au Nanoplates with Exceptional Stability for Highly Sensitive Colorimetric and Photothermal Dual-Mode Lateral Flow Immunoassay},
journal = {Analytical Chemistry},
year = {2024},
doi = {10.1021/acs.analchem.3c05787}
}
EUVIMED