A Portable Microplasma Optical Emission Spectrometric Device with Online Digestion Function for Field and Sensitive Determination of Lead in Biological Samples
Analytical Chemistry · 05.03.2024 · 96 (9) · 3733-3738
DOI: 10.1021/acs.analchem.3c05330 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 19.02.2024. Verfasst von Ji-Ying Cai und 5 weiteren Autor:innen. Beteiligte Einrichtung: Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China. Hauptthemen laut MEDLINE: Lead, Optical Devices. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 32 Literaturangaben. Gefördert von: Fundamental Research Funds for the Central Universities, National Natural Science Foundation of China.
Abstract (Originalsprache)
Accurate detection and screening of Pb in biological samples is helpful to assess the risk associated with lead pollution to human health. However, conventional atomic spectroscopic instruments are bulky and cumbersome, requiring additional sample pretreatment equipment, and difficult to perform field analysis with. Herein, a portable point discharge (PD) microplasma-optical emission spectrometric (OES) device with online digestion function is designed for field and sensitive determination of lead in biological samples. With rice as a model, online digestion of a batch of six 50 mg samples can be achieved in the HNO3 and H2O2 system within 25 min by a temperature control and timing module. Compared to the conventional microwave digestion, the digestion efficiency of this device reaches 97%. Pb in digestion solution is converted into volatile species by hydride generation (HG) and directly introduced into PD-OES for excitation and detection by a self-designed rotatable and telescopic cutoff gas sampling column. Six samples can be successively detected in 2 min, and argon consumption of the whole process is only
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Box 332, Shenyang 110819, China.
ORCID-Profile: Shuai Chen, Yong-Liang Yu, Jian-Hua Wang
Förderung
- Fundamental Research Funds for the Central Universities
- National Natural Science Foundation of China
Zitieren
APA
Cai, J. Y., Zhang, X., Wei, Y. J., Chen, S., Yu, Y. L., & Wang, J. H. (2024). A Portable Microplasma Optical Emission Spectrometric Device with Online Digestion Function for Field and Sensitive Determination of Lead in Biological Samples. Analytical Chemistry, 96(9), 3733-3738. https://doi.org/10.1021/acs.analchem.3c05330
Vancouver
Cai JY, Zhang X, Wei YJ, Chen S, Yu YL, Wang JH. A Portable Microplasma Optical Emission Spectrometric Device with Online Digestion Function for Field and Sensitive Determination of Lead in Biological Samples. Analytical Chemistry. 2024;96(9):3733-3738. doi:10.1021/acs.analchem.3c05330
BibTeX
@article{Cai2024,
author = {Cai, Ji-Ying and Zhang, Xiao and Wei, Yu-Jia and Chen, Shuai and Yu, Yong-Liang and Wang, Jian-Hua},
title = {A Portable Microplasma Optical Emission Spectrometric Device with Online Digestion Function for Field and Sensitive Determination of Lead in Biological Samples},
journal = {Analytical Chemistry},
year = {2024},
volume = {96},
number = {9},
pages = {3733--3738},
doi = {10.1021/acs.analchem.3c05330}
}