EUVIMEDEUVIMED entdecken
Crossref

SCALiR: A Web Application for Automating Absolute Quantification of Mass Spectrometry-Based Metabolomics Data

Luis F Ponce, Stephanie L Bishop iD, Soren Wacker iD, Ryan A Groves, Ian A Lewis iD

Analytical Chemistry · 30.04.2024 · 96 (17) · 6566-6574

DOI: 10.1021/acs.analchem.3c04988 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Analytical Chemistry, online erschienen am 20.04.2024. Verfasst von Luis F Ponce und 4 weiteren Autor:innen. Beteiligte Einrichtung: Alberta Centre for Advanced Diagnostics, Department of Biological Sciences, University of Calgary, 2500 University Dr NW, Calgary, AB T2N 1N4, Canada. Hauptthemen laut MEDLINE: Metabolomics, Software, Mass Spectrometry. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Government of Canada, Alberta Innovates, Thermo Fisher Scientific.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Quantitative liquid chromatography-mass spectrometry (LC-MS)-based metabolomics is becoming an important approach for studying complex biological systems but presents several technical challenges that limit its widespread use. Computing metabolite concentrations using standard curves generated from standard mixtures of known concentrations is a labor-intensive process that is often performed manually. Currently, there are few options for open-source software tools that can automatically calculate metabolite concentrations. Herein, we introduce SCALiR (standard curve application for determining linear ranges), a new web-based software tool specifically built for this task, which allows users to automatically transform LC-MS signals into absolute quantitative data (https://www.lewisresearchgroup.org/software). SCALiR uses an algorithm that automatically finds the equation of the line of best fit for each standard curve and uses this equation to calculate compound concentrations from the LC-MS signal. Using a standard mix containing 77 metabolites, we show a close correlation between the concentrations calculated by SCALiR and the expected concentrations of each compound (R2 = 0.99 for a y = x curve fitting). Moreover, we demonstrate that SCALiR reproducibly calculates concentrations of midrange standards across ten analytical batches (average coefficient of variation 0.091). SCALiR can be used to calculate metabolite concentrations either using external calibration curves or by using internal standards to correct for matrix effects. This open-source and vendor agnostic software offers users several advantages in that (1) it requires only 10 s of analysis time to compute concentrations of >75 compounds, (2) it facilitates automation of quantitative workflows, and (3) it performs deterministic evaluations of compound quantification limits. SCALiR therefore provides the metabolomics community with a simple and rapid tool that enables rigorous and reproducible quantitative metabolomics studies.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MetabolomicsSoftwareMass SpectrometryChromatography, LiquidInternetAlgorithmsAutomationAnimals

Autor:innen und Institutionen

  • Alberta Centre for Advanced Diagnostics, Department of Biological Sciences, University of Calgary, 2500 University Dr NW, Calgary, AB T2N 1N4, Canada.

ORCID-Profile: Stephanie L Bishop, Soren Wacker, Ian A Lewis

Förderung

  • Government of Canada
  • Alberta Innovates
  • Thermo Fisher Scientific
  • Canada Foundation for Innovation
  • U.S. Department of Health and Human Services
  • Genome Canada
  • PrairiesCan

Zitieren

APA

Ponce, L. F., Bishop, S. L., Wacker, S., Groves, R. A., & Lewis, I. A. (2024). SCALiR: A Web Application for Automating Absolute Quantification of Mass Spectrometry-Based Metabolomics Data. Analytical Chemistry, 96(17), 6566-6574. https://doi.org/10.1021/acs.analchem.3c04988

Vancouver

Ponce LF, Bishop SL, Wacker S, Groves RA, Lewis IA. SCALiR: A Web Application for Automating Absolute Quantification of Mass Spectrometry-Based Metabolomics Data. Analytical Chemistry. 2024;96(17):6566-6574. doi:10.1021/acs.analchem.3c04988

BibTeX
@article{Ponce2024,
  author = {Ponce, Luis F and Bishop, Stephanie L and Wacker, Soren and Groves, Ryan A and Lewis, Ian A},
  title = {SCALiR: A Web Application for Automating Absolute Quantification of Mass Spectrometry-Based Metabolomics Data},
  journal = {Analytical Chemistry},
  year = {2024},
  volume = {96},
  number = {17},
  pages = {6566--6574},
  doi = {10.1021/acs.analchem.3c04988}
}
Kostenlos starten →